Datexel DAT 3016 Manual

4 channel thermocouple to rs485 converter

Advertisement

Quick Links

Thermocouple RS485 Converter 4 channel
Phone: +1 561 779 5660 E-mail : Info@datexel.com - Web Site www.datexel.com
FEATURES
- Field-Bus remote data acquisition
- Modbus Slave device on RS-485
- Modbus RTU/ Modbus ASCII protocol
- 4 channels input
- Input configurable for Tc J, K, R, S, B, E, T, N and voltage up to ± 1V
- Watch-Dog Alarm
- Remotely Configurable
- 2000 Vac 3-ways Galvanic Isolation
- High Accuracy
- UL / CE mark
- DIN rail mounting in compliance with EN-50022
GENERAL DESCRIPTION
The DAT 3016 device is able to acquire up to 4 analogue input signals. The data are transmitted with MODBUS RTU/MODBUS ASCII protocol on the RS-485
network (RS-232 interface is available).
It is possible to connect on input thermocouples or voltage signals up to ± 1V . The Cold Junction compensation for thermocouples is internally performed.
The device guarantees high accuracy and stable measure versus time and temperature.
To ensure the plant safety, two Watch-Dog timer alarms are provided.
The isolation between the parts of circuit removes eventual ground-loop effects, allowing the use of the device even in the heavy environmental conditions.
The DAT 3016 is in compliance with the Directive UL 61010-1 for US market and with the Directive
The device is housed in a rough self-extinguishing plastic container which, thanks to its thin profile of 17.5mm only, allows a high density mounting on EN-50022
standard DIN rail.
COMMUNICATION PROTOCOLS
The DAT3016 is designed to work with the MODBUS RTU/MODBUS ASCII protocol: standard protocol in field-bus; allows to directly interface DAT3000 series
devices to the larger part of PLCs and SCADA applications available on the market.
For the protocol instructions, refer to the User Guide of the device.
USER INSTRUCTIONS
Before to install the device, please read the "Installation Instruction" section.
If the module configuration is unknown, with device powered off, connect the INIT terminal to the GND terminal (ground), at the next power on the device will be
auto-configured in the default settings (refer to the User Guide of the device).
Connect power supply, serial bus and analogue inputs as shown in the "Wiring" section.
The "PWR" LED state depends on the working condition of the device: see the "Light Signalling" section to verify the device working state.
To perform configuration and calibration operations, read the instructions in the User Guide of the device.
To simplify handling or replacing of the device, it is possible to remove the wired terminals even with the device powered.
INPUT
Input type
Min
Voltage
25 mV
-25 mV
100 mV
-100 mV
250 mV
-250 mV
1000 mV
-1000 mV
Thermocouple
J
-210 °C
K
-210 °C
R
-50 °C
S
-50 °C
B
+400 °C
E
-210 °C
T
-210 °C
N
-210 °C
(1) Referred to input Span (difference between max. and min.
Values)
(2) A pull-up resistor (10MW) is connected to +1V (break sensor)
TECHNICAL SPECIFICATIONS (Typical @ 25 °C and in the nominal conditions)
Input Accuracy (1)
mV/Tc
Max
Linearity (1)
mV
+25 mV
Tc
+100 mV
+250 mV
Cold Junction Compensation ± 0.5 °C
+1000 mV
Input Impedance
+1200 °C
+1372 °C
mV, Tc
+1767 °C
+1767 °C
Thermal drift
+1825 °C
Full Scale
+1000 °C
+400 °C
CJC Thermal drift
+1300 °C
Full Scale
Lead wire resistance influence
mV, Tc
Sample time
Data Transmission
Baud Rate
Max. distance
Warm-up time
4 channel Thermocouple to RS485
CSA C22.2 No 61010-1 for the
POWER SUPPLY
Power supply voltage
the higher of
Reverse polarity protection
± 0.05% or 5 uV(1)
Current consumption
± 0.1% f.s. (1)
ISOLATION
± 0.2% f.s. (1)
Input – RS485
Supply – Input
Supply – RS485
ENVIRONMENTAL CONDITIONS
>/= 1 MW (2)
Operative Temperature
UL Operative Temperature
Storage Temperature
± 0.005 % / °C (1)
Humidity (not condensed)
Maximum Altitude
Installation
± 0.02 %/ °C
Category of installation
Pollution Degree
MECHANICAL SPECIFICATIONS
< 0.8 uV/Ohm (1)
Material
IP Code
0.5 ÷ 1 sec.
Wiring
Tightening Torque
38.4 Kbps
Mounting
1.2 Km – 4000 ft
Weight
3 min.
CERTIFICATIONS
EMC ( for industrial environments)
Immunity
Emission
UL
US Standard
Canadian Standard
CCN
Typology
Classification
File Number
Converter
D
A
T
3
016
D
A
T
3
016
Canadian market.
10 .. 30 Vdc
60 Vdc max
30 mA max.
2000 Vac 50 Hz, 1 min.
2000 Vac 50 Hz, 1 min.
2000 Vac 50 Hz, 1 min.
-10°C .. +60°C
-10°C .. +40°C
-40°C.. +85°C
0 .. 90 %
2000 m
Indoor
II
2
Self-extinguish plastic
IP20
wires with diameter
0.8÷2.1 mm
2
/AWG 14-18
0.5 N m
in compliance with DIN rail
standard EN-50022
about 150 g.
EN 61000-6-2
EN 61000-6-4
UL 61010-1
CSA C22.2 No 61010-1
NRAQ/NRAQ7
Open Type device
Industrial Control
Equipment
E352854

Advertisement

loading

Summary of Contents for Datexel DAT 3016

  • Page 1 - DIN rail mounting in compliance with EN-50022 GENERAL DESCRIPTION The DAT 3016 device is able to acquire up to 4 analogue input signals. The data are transmitted with MODBUS RTU/MODBUS ASCII protocol on the RS-485 network (RS-232 interface is available).
  • Page 2: Installation Instructions

    DAT 3016 / 485 / Tc K Interface type Input type 485 : RS-485 232 : RS-232 = Requested 17.5 = Optional Datexel s.r.l. reserves its right to modify the characteristics of its products totally or in part without warning at any time. ED.03.15 REV.01...