Kit VIDEO DIGITAL
Kit VIDEO DIGITAL
KIT WIRING DIAGRAM
A 10 Kohm resistance must be
placed between the + and L
monitor terminals. A bag with 5
resistors is included with the Kit.
Vac
+
POWER
SUPPLY
NOTE: The power supply may be located
at an intermediate point of the
installation. Maximum distance to panel:
30 metres.
JP2
Ct L
S
+ -
CT
12 Vdc
NOTE: The use of unscreened cable may give rise
to greater sensitivity to radio-electric radiation.
Pag 26
-
+
-
-
EXT.
ADS KIT
PLAC
AMPLIFIER
INT.
TELEFONO
C
Nc
-
+
B
B
No
+12
CAMERA
V M
..........
.......... ....
....
* Installation with UTP CAT 5 4-pair Cable,
up to a maximum distance of 100 metres.
* Installation with standard cable (5 wires),
up to a MAXIMUM distance of 50 metres with
0.5 mm
M
V
+
L
For distances over 50 metres or
additional equipment:
NOTES:
For optimum image quality, use coaxial
cables if the distance is greater than 50
metres.
If you have additional cables in the tubing, duplicate
the negative "-" wire.
Do not mix cables from different sections, or splice
the video wires.
M
V
V
M
10 Kohm
+
L
-
Ct
+A
-A
T
J1 PRG
T
LE
cable section.
2
DISTANCE
CROSS
SECTION
(meters)
1 a 50
1
mm
50 a 100
1,5
mm
100 a 200
2,5
mm
V
M
+
-
L
V
M
+
-
L
2
2
2