Appliance Description; Operation; Switching The Appliance On Without Hirschmann Plug-In Connection; Switching The Appliance On With Hirschmann Plug-In Connection - AEG IR Premium 1650 Operation And Installation

Ir short wave radiant heater
Hide thumbs Also See for IR Premium 1650:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 12

3. Appliance description

The appliance only warms the air slightly. It is only when it hits objects or the human body that the IR radiation is converted
into heat. You will feel the heat after just a few seconds. The appliance therefore provides energy-saving heat, which is avail-
able quickly and on demand at any time.
The appliance is made completely from stainless steel. The appliance can be exposed to normal environmental influences.

4. Operation

4.1

Switching the appliance on without Hirschmann plug-in connection

» Start the appliance by pushing the power plug into its socket.

4.2 Switching the appliance on with Hirschmann plug-in connection

» If not already in place, connect the power cable with the cable with mains plug.
» Start the appliance by pushing the power plug into its socket.

4.3 Switching OFF the appliance

» Switch off the appliance by pulling the power plug from its socket.

5. Cleaning, care and maintenance

Never spray the appliance with water. Never immerse the appliance in water.
Never touch the quartz rods with fingers, otherwise spots could form or the quartz rods could be damaged.
» Switch off the appliance and let it cool down.
» A damp cloth is sufficient for cleaning the casing. Never use abrasive or corrosive cleaning agents. Go over with a soft
cloth.
» Regularly clean the reflector through the grille using a paint brush. Let a contractor clean the reflector if it is heavily
soiled to retain the full level of heat radiation of this appliance.
The heating tube (gold tube) has a maximum service life of approx. 5000 hours. It is subject to the operating conditions, such
as the relative humidity, switching frequency and the orientation of the radiant heater.

6. What to do if ...

6.1

... you notice a smell

º For a short time after first taking the appliance into use as well as after longer breaks in use, a smell may develop.

6.2 ... the appliance does not radiate heat

º Check whether the fuses/MCBs have blown/tripped or are faulty.
If you cannot remedy the fault, notify your heating contractor. To facilitate and speed up your enquiry, please provide the
serial number from the type plate (no. XXXXXX - XXXX - XXXXXX):

6.3 The type plate

The type plate is located at the back of the appliance.
Operation - for users and contractors
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir premium 2000Ir premium 2000 hIr premium 2000 cl

Table of Contents