Operation; Zero The Display; Taring; Weighing Unit Shift - Baxtran DIM Series User Manual

Top loading scale
Table of Contents

Advertisement

Available languages

Available languages

Model DIM

03. oPeration

3.1. Zero tHe disPlaY

You can press the
measured, within 2% of power up zero. This will usually only be necessary when the pan is empty. When the
zero point is obtained the display will show indicator for zero.
The scale has an automatic rezeroing function to account for minor drifting or accumulation of material on
the platform. However you may need to press the
shown when the platform is empty.

3.2. taring

Zero the scale by pressing the
Place a container on the pan a value for its weight will be displayed.
Press the
key to tare the scale. The weight that was displayed is stored as the tare value and that value is
subtracted from the display, leaving zero on the display.
The "NET" indicator will be on. As product is added only the weight of the product will be shown.
When the container is removed a negative value will be shown. If the scale was tared just before removing the
container this value is the gross weight of the container plus all products that was removed.
The zero indicators will also be on because the platform is back to the same condition it was when the
key was last pressed.

3.3. weigHing unit sHift

Press
key and
mark turn on (kg or g).

04. Parameters and calibration

4.1. enter setting mode

To set parameters, first turn on the weighing scales, hold the
"F1 CAL".

4.2. calibrate

After enter setting mode, the display will show "F1 CAL". press
platter, after STABLE indicator on, press
key to select calibrate weight, after you select, put the calibrate weight on, after STABLE indicator on, press
key to sure, scale will auto restart. calibration finished.

4.3. cHange caPacitY

After enter setting mode, the display shows "F1 CAL", press
press the
Key to enter, press the
sure.

4.4. set resolution

After enter setting mode, the display shows "F1 CAL", press the
key to enter, press the

4.5. cHecK internal counts

After enter setting mode, display shows "F1 CAL", press
to enter, display shows internal counts, press
4.6. set auto Power off time
After enter setting mode, display shows "F1 CAL", press
key to enter, display shows current turn off time, this function have four model, include(3/5/15MIN/
OFF), press the
key to return setting mode.
key at any time to set the zero point from which all other weighing and counting is
key if necessary. The zero indicator will be on.
key to together will change weighing unit in the weight mode, relevant weighing unit
key again, display shows the calibrate weight, you can press
key to enter, press
key select current resolution. Press the
key to rezero the scale if small amounts of weight are
key during self-checking, until display show
key, display shows "UNLD", empty the
key select , until display shows "F3 CAP ",
key to select capacity , press zero key to
key display shows "F2 RES " press the
key select , display shows "F4 INP", press
key to return setting mode.
key select , until display shows "F5 oFF", press
User's Guide
key confirms.
key
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dim 3Dim 6Dim 15

Table of Contents