Tebis TX100 Configurator
Electrical / Mechanical characteristics: see product user's instructions
Product designation
Consumption indicator
Consumption indicator TE331
Tariff
Measurement of
electricity consumption
Temperature
measurement
1
Consumption indicator TE331
TP device
TX100 version
RF device
> 2.7.58
Products KNX
Display
(Only for France)
6T 8722-02a

Advertisement

Table of Contents
loading

Summary of Contents for hager Tebis TX100

  • Page 1 Tebis TX100 Configurator Consumption indicator TE331 Electrical / Mechanical characteristics: see product user's instructions TP device Product reference Product designation TX100 version RF device TE331 Consumption indicator > 2.7.58 Products KNX Input modules Consumption indicator TE331 Display Tariff Measurement of...
  • Page 2: Table Of Contents

    Summary 1. Description of the system..............................3 1.1 General overview................................. 3 1.2 General outline ................................4 2. Presentation of the functions ............................5 2.1 Main functions overview .............................. 5 2.2 Description of measurement............................6 2.3 Possible installations ..............................9 2.4 "Tele-information" Tariff Description.......................... 10 2.5 Description of temperature measurement .........................
  • Page 3: Description Of The System

    1. Description of the system 1.1 General overview The consumption indicator informs users of their consumption through several metering channels including one specifically dedicated to "Tele-information"*. It is used to monitor and control energy consumption and is built into an automatic global energy management system.
  • Page 4: General Outline

    1.2 General outline Room programmer 6 zones TYD480 Clock TX022, TX023 domovea TJA450 Ranges clock: N L1 L2 L3 N L1 L2 L3 TE331 TE331 EG103x, EG203x T1 / T2 All other meters with tariff relay by dry contact 230V (T1=0V, Tele-info T2=230V) Temperature sensor...
  • Page 5: Presentation Of The Functions

    2. Presentation of the functions 2.1 Main functions overview ■ Tariff The function is used to: • Supply the value of the current tariff on the bus for an ambiance display, • Supply the value of the coming tariff on the bus for display in ambiance - only available with Tele-information, •...
  • Page 6: Description Of Measurement

    2.2 Description of measurement The consumption indicator has 7 measurement channels: - 3 physical channels used to measure voltage and current, - 1 virtual channel tele-information used to measure the total consumption, - 1 virtual channel addition used to add up the physical channels, - 1 virtual channel others used to calculate the difference between the tele-information channel and the physical channels, - 1 virtual channel three-phase uniting the 3 physical channels to create a single channel.
  • Page 7 • 1 measurement channel by addition of the channels ADDITION METERING "Addition" power meter Send measurement Measurement by "Addition" total energy meter adding the channels "Addition" partial energy meter Meter reset The channels are added as follows: • Channels 1, 2 and 3 •...
  • Page 8 Installation type This product can be used in a single-phase or three-phase installation. Three-phase consumption can be measured on each phase. The measurement is an absolute value. The measurement channels are used to meter either consumption of energy production (e.g. in the case of a photovoltaic installation).
  • Page 9: Possible Installations

    2.3 Possible installations Possible installations are given below for the configuration of the electricity metering channels only. Installation type Input x Input y Input z Additional settings Electrical heating + DHW boiler Heating Sockets Heat pump + DHW boiler 2 in 1 heat pump (Heating + Not used or sockets Heating / cooling dates (See Heating / DHW...
  • Page 10: Tele-Information" Tariff Description

    ■ Example 2: 2 in 1 heat pump (Heating + DHW) Others Sockets DHW / Heating Channel settings: Channel x: Heating / DHW Channel y: Sockets with, for example, Ground floor sockets as a label Channel z: Sockets with, for example, First floor sockets as a label Others = TIC* - (Heating + DHW + Sockets) ■...
  • Page 11: Te331 Inputs And Outputs

    3. TE331 inputs and outputs ■ Energy saving function Inputs Numbering Outputs 1 temperature channel +info ■ Energy management function Inputs Numbering Outputs 7 metering channels (3 strength of current transformers + the tele-info link + addition + other + three-phase) +info 1 tariff information channel 4.
  • Page 12: Display Of The Input Numbering

    5. Display of the input numbering Once the consumption indicator (TE331) has been recognised by the TX100, the inputs are automatically recognised and visible only in "+info" mode. Note the numbers of the inputs, by pressing each push button as shown in the table below. Push button Input Icon...
  • Page 13: Configuration And Setting In Standard Mode

    • Extension of the communication system: Used to access the group address given during programming in Standard mode in order to create links between a Tebis TX installation (TP, radio KNX) and Hager such as technical alarms, display, domovea server, •...
  • Page 14: Easy Prog Mode

    8.2 Easy Prog mode In this mode it is possible to: • Display all the links creaed manually and automatically, • Delete the links created manually and automatically. The table here after shows all type of links compatible with the product: Possible link type Input Link description...
  • Page 15: Info Mode

    ■ Objects appearing for the TE331 Designation TX100 ETS objects designation Description OutTemp Temperature Temperature - Emission Used to send the temperature. Used to index the partial and total energy Tariff Tariff Metering - Current tariff values. Power Power Metering - Power Used to display the instantaneous power.
  • Page 16: Configuration And Use With Domovea

    9. Configuration and use with domovea The domovea configuator has an "Energy management" type device for the electricity meter. Functions available: - Electrical power: Used to display the consumed electrical power value (in W). - Electrical energy: Used to display the consumed electrical energy value (in kWh). - Tariff indication: Used to display the current tariff.
  • Page 17: Importation Of Group Addresses

    9.2 Importation of group addresses Execute the following steps: • Select the "Devices" tab, • Select a device (E.g. meter), • Click on "See the KNX data / "Configure by TX100", • Click on "Import" and select the TX100 (*.TXH) project backup file, •...
  • Page 18: Choice Of Tariff Under Domovea

    9.3 Choice of tariff under domovea Domovea allows a tariff to be defined according to the offer subscribed to. To to so, click on the "Measurements" tab for the device used, then on "Subscription". Define your subscription by clicking on "Chose a subscription model". Domovea has tariff models according to the country (France or Germany) and a personalised model (configurable).
  • Page 19 Type Option Identifier Name Einzeltarif Basic German Tariff 1 (More expensive) Doppeltarif Tariff 2 Basic Basic Heure creuse Heure pleine / Heure creuse Heure pleine Blue HC Blanc HC France Red HC Tempo Blue HP Blanc HP Red HP Normal day Peak day Tariff 0 Tariff 1...
  • Page 20: Operation

    10. Operation 10.1 Installation 2 4 6 8 10 1214 16 18 20 Remark: The 3 buttons are only used for configuration with the TX100. 10.2 Meaning of the LED's TE331 6T 8722-02a...
  • Page 21 Channel Function LED 1 LED 2 LED 3 LED 4 Activated Deactivated Tele-info (Only in Communication France) error or error on the Flashing channel Flashes for every 1 Operating Wh consumed No bridging in Channel 1 Flashing at a single phase or no frequency of 0.5 phase in three- phase...
  • Page 22: Current Outage And Return

    10.3 Current outage and return The consumption indicator requires mains power and a power supply to the KNX bus to operate. Mains power fault: After 60 s, the energy, current, voltage and power data returns to 0 and is still sent on the bus according to the defined period.
  • Page 23 TE331 6T 8722-02a...
  • Page 24: Other Functions

    11. Other functions ■ Restore Factory Configuration function This function enables the device to be returned to its initial configuration (configuration when it came out of the factory). After a factory reset, the product can be reconfigured or reused in a new installation.. This function is accessible via the TX100's Device Management / Reset menu.
  • Page 25 TE331 6T 8722-02a...