Basic Wiring Diagram; Wiring System Diagram For Multiple Remote Controllers - Panasonic CZ-24KPU1U Series Installation Instructions Manual

Single split system air conditioner
Hide thumbs Also See for CZ-24KPU1U Series:
Table of Contents

Advertisement

5-18. Wiring System Diagram for Multiple Remote Controllers

When installing multiple remote controllers
This multiple system is used for operating the unit(s) at
different positions. (A maximum of 2 signal receiving
units can be installed.)
Setting method
To execute this control, make the setting according
to the following procedure.
(1) Of the two installed signal receiving units, make
one the main signal receiving unit (factory-shipped
state).
(2) On the other signal receiving unit, change the
address connector on the PCB from main to sub
position.
In this state, it functions as a sub-signal receiving
unit.

Basic wiring diagram

CAUTION
To operate 1 indoor unit with 2 signal receiving units
set at different locations.
Panasonic̲PAC-i̲IndoorUnit̲US-le52   52
Panasonic̲PAC-i̲IndoorUnit̲US-le52   52
Carry out the wiring correctly
(incorrect wiring will damage
the equipment).
Signal receiving unit
(main)
(sub)
(Option)
1 2
1 2
Connection wiring
Remote control
cable terminal
1 2
board
Indoor unit
Earth
52
2011/11/02   15:17:38
2011/11/02   15:17:38