3.4
Installation diagram
The figure shows the Installation diagram. This diagram is referred to in the sections describing the actual connection procedure.
Installation diagram: Theta dual service with a BFC - Unvented.
Legend
1.
pressure relief valve (mandatory if the
mains water pressure is too high)
3.
T&P valve (mandatory)
4.
stop valve (recommended)
5.
non-return valve (mandatory)
6.
circulation pump (optional)
9.
drain valve
10. manual gas valve (mandatory)
11. service stop valve (recommended)
12. temperature gauge (optional)
13. condensation drain
14. draw-off point
15. expansion valve (mandatory)
16. expansion vessel (mandatory)
70
Installation-, User- and Service Manual
20. heating pump (mandatory)
22. radiator
23. pressure valve (mandatory)
26. heating filling tap (recommended)
32. floor heating
33. room thermostat
40. DHW-pump
42. control Theta dual service module
56. pressure valve (recommended)
57. filling and draining valve (mandatory)
59. 3-way mixing valve (mandatory)
A. cold water supply
B. hot water supply
C. circulation pipe
D. gas supply
IMD-1126b R0.0
hot water supply 3-way mixing valve
from water heater
outlet 3-way mixing valve to plate heat
exchanger
return water to 3-way mixing valve
from plate heat exchanger
S
heating system sensor