Dual service module for heating and domestic hot water
Table of Contents

Advertisement

Available languages

Available languages

Installation-, User- and Service Manual
TERMINAL STRIP CONNECTIONS:
Earth
N
Neutral
L
Live input of controller
L
Live input for 3-way mixing valve (warm water supply of water heater)
1
L
Live input for 3-way mixing valve (return water of plate heat exchanger)
2
L
Live input for solar heating system modulating pump (PWM)
3
L
Live input for heating pump
5
L
Live input for DHW pump
6
L
Live output of Switched Live room thermostat
7
PWM + PWM+ signal of solar heating system pump (modulating)
PWM - PWM- signal of solar heating system pump (modulating)
COMPONENTENS:
AA
Controller of solar heating system (SHM 3.0)
BB
3-way mixing valve (230 V
CC
Heating pump (230 V
DD
DHW pump (230 V
EE
Temperature sensor (S
FF
Room thermostat (24 V
GG
Room thermostat (230 V
HH
Communication between the water heater controller and the solar heating
system controller
JJ
Solar heating system pump (modulating) (230 V
[VAC]
JJ
Solar heating system pump (modulating) (PWM-signal)
[PWM]
KK
Temperature sensor (S
LL
Temperature sensor (S
MM
Combined Q/T sensor incl. temperature sensor
- solar collector return) (12 kΩ NTC)
(S
4
K
Double-pole isolator
CONTROLLER CONNECTIONS:
J3
Connection of room thermostat (ON/OFF)
J12
Connection combined Q/T sensor (1-2-3-4)
J13
Connection of temperature sensor S
J14
Connection of temperature sensor S
J16
Connection of BUS-link communication
J18
Connection of PWM-signal solar heating system pump
F2
Fuse (T 3,15 A - 250 V)
)
AC
)
AC
)
AC
- heating system)
5
- ON/OFF)
AC
- Switched Live)
AC
-solar collector) (20 kΩ NTC)
1
- tank) (12 kΩ NTC)
2
(1-3) and temperature sensor S
5
(2-4)
2
)
AC
(2-4)
1