DIGITAL KEY TELEPHONE SYSTEM
b) Analog CO with WTIB (wireless terminal)
CO
32
1)
28
24
20
16
12
BKSU only
08
04
00
00
12
76
Figure 2.2.2.2.c
Analog CO and 12 port Extension Board
!
Note
1) This is only the configuration chart when a customer uses the maximum wireless
terminals with RMWT 64. If RMWT is set by another value, above will be different
configuration chart according to the RMWT.
RMWT can set by multiple of 8 in the range of 8 to 64. A customer can program this RMWT
(default 8) in Admin field 02, Flexible button 3.
!
RMWT: Registrable Maximum number of Wireless Terminal. For more details, refer to
Installation and Maintenance Manual of GDK-162/100/FPII WOTS (Wireless Office
Telephone System)
2) See the description on clause 2.2.2.2.a - Note 1) and 2), in relation to the configuration with 6
port extension boards and 2B module.
BKSU and
EKSU
88 100
112 124 136
Stations
Configuration with
CO
32
1)
28
24
20
16
12
BKSU only
08
04
00
00
12
24
Figure 2.2.2.2.d
CO and 24 port Extension Board
7
BKSU
and
EKSU
88
100
112 124 136
Stations