D X-3 001H 9- V In dus tr ia l 3 G /WAN VPN Rou te r User M an ua l
Working Mode
Select the working mode for the current active serial port.
Master mode: This mode is suitable for the DX-3001 to perform the
read/write tasks on the open register of the Slave.
Close: Disable this functionality.
Baud Rate
Set up the baud rate for the serial port. Options are 2400, 4800, 9600, 19200,
38400, 57600 and 115200.
Data Bits
_3
Set up the data bits for the serial port.
Stop Bits
Set up the stop bits for the serial port. Options are 1 and 2.
Parity Bits
Set up the parity bits for the serial port. Options are None, Odd and Even.
Flow Control
Set up the flow control. Options are None, XON, XOFF, RTS, and CTS.
MODBUS Mode
Set up the communication mode for the device.
MODBUS Timeout
Set up the timeout timer from 50ms to 2000ms. If the set value is out of range,
it will be automatically changed to its maximum or minimum value.
3.5.3

Profile Management

This page is used for setup the parameter about data collect.
3 - 4 2
Description
Default
Close
9600
8
1
None
None
MODBUS RTU
1000ms