  • Page 1 100BASE-T1 MEDIACONVERTER USER MANUAL July 2020 Manual-Version: 2.5 Hardware-Version: 2.0 to 3.0.a...
  • Page 2: Table Of Contents

    LINKS ......................4 1.1.4 General operating and safety strategy of Technica Engineering’s Products 1.1.5 General design rules for the power supply of Technica Engineering’s products ........................5 Warranty and Safety Information ............... 5 RoHS Certificate of Compliance ................ 7 Scope of Delivery ....................8 HARDWARE INTERFACES ..................
  • Page 3: General Information

    1 GENERAL INFORMATION 1.1 Functionality and Features of the 100BASE-T1 MediaConverter_BCM Figure 1-1: 100BASE-T1 MediaConverter_BCM The Technica Engineering 100BASE-T1 MediaConverter_BCM transmits data frames directly from the physical layer BroadR-Reach (100BASE-T1) to Fast Ethernet (100BASE-TX) with constant delay time of 2.0µs. 1.1.1...
  • Page 4: General Information

    Should Technica Engineering’s products be operated in voltage ranges beyond those specified in the norms, which represents a breach of the conditions of operation, then this will void the product warranty and Technica Engineering will assume no liability whatsoever of the results and/or consequences thereof.
  • Page 5: General Design Rules For The Power Supply Of Technica Engineering's Products

    General design rules for the power supply of Technica Engineering’s products The power supply circuit of Technica Engineering’s products are equipped with self- protection components. This automatic function protects the devices against excessive temperature and too high supply-voltage by switching the device off. This automatic switch-off function is independent of any software function.
  • Page 6 When integrating the modules in a vehicle or test set-up, the user must ensure appropriate ventilation or air convection. Technica Engineering products must not be considered as a safety element out of context when using safety-critical systems and must be included in the safety assessment when used. The development class in a safety system must be taken into account with standard QM referred to ISO26262.
  • Page 7: Rohs Certificate Of Compliance

    1.3 RoHS Certificate of Compliance Figure 1-2 Copy of RoHS Certificate of Compliance 100BASE-T1 MediaConverter_BCM User Manual...
  • Page 8: Scope Of Delivery

    1.4 Scope of Delivery The delivery includes: 1x 100BASE-T1 MediaConverter BCM 1x 1m Ethernet Cable 1x Black MQS Connector 1x 1m 100BASE-T1 Cable MQS crimp contacts 100BASE-T1 MediaConverter_BCM User Manual...
  • Page 9: Hardware Interfaces

    2 HARDWARE INTERFACES 2.1 Connectors On the label on top of the device you can see an overview about all HW interfaces of the 100BASE-T1 MediaConverter_BCM. Figure 2-1: Label of 100BASE-T1 MediaConverter_BCM 2.1.1 Black MQS Connector The pinning of the ECU connectors is listed on the label on top of the device as well. (See 2-1).
  • Page 10: Rj45 Ethernet Connectors

    The Tyco Electronics (TE) Micro Quad Lock System (MQS) is used. Name Picture Part Number Tyco, MQS Abdeckkappe 2x9 Pol, black 1-967416-1 Alternative 1-1355350-1 Tyco, MQS Buchsengehäuse 2x9 Pol 965778-1 Alternative 962108-2 Tyco crimp contact 928999-1 Table 2—1: Parts of black MQS connector Note: You can use the official Tyco tool for these crimp contacts.
  • Page 11: Other Interfaces

    2.2 Other Interfaces 2.2.1 DIP-Switches The 100BASE-T1 MediaConverter_BCM has two DIP switches for configuration (see HAPTER 2.2.2 Status LEDs The 100BASE-T1MediaConverter_BCM has two status LEDs at the frontside of the case for the 100BASE-T1 Port. Upper LED: Green Color. It is lit when there is a linkup on the 100BASE-T1 port. Lower LED: Yellow Color.
  • Page 12: Configuration Of The Device

    3 CONFIGURATION OF THE DEVICE The 100BASE-T1 MediaConverter is configured by two DIP switches on the front of the device. DIP-Switch Status Description ON (up) 100BASE-T1 Port is set to Master OFF (down) 100BASE-T1 Port is set to Slave ON (up) 100BASE-T1 Port is set to FullOut OFF (down) 100BASE-T1 Port is set to HalfOut...
  • Page 13: Standard Use Case

    4 STANDARD USE CASE Here you can see a standard use case of the 100BASE-T1 MediaConverter_BCM: Figure 4-1: Example for use case MediaConverter DUT: Device under Test. DIP switch 2 should be always ON, DIP switch 1 is dependent of the DUT. If DUT is Master, MC must be configured as Slave (DIP-switch 1: OFF) and vice versa.
  • Page 14: 100Base-T1 Filter

    5 100BASE-T1 FILTER There are different BroadR-Reach filters in different hardware versions of the 100BASE-T1 MediaConverter_BCM: The following 100BASE-T1 filter is used in the hardware version 3.0: In Version 3.0 the Würth CMC 510010003 is used for L32. In Version 3.0a the TDK CMC ACT45L - 2 01 - 2P is used for L32. Figure 5-1: 100BASE-T1 filter for HW v3.0 and v3.0a The following 100BASE-T1 filter is used in the hardware version 2.0: Figure 5-2: 100BASE-T1 filter for HW v2.0...
  • Page 15: Additional Information

    6 ADDITIONAL INFORMATION The delay time is constant 2.0µs. The delay is independent from the ethernet packet frame size. The 100BASE-T1 MediaConverter_BCM is optimized for automotive use. The maximum cable length for 100BASE-T1 segments is limited to 15 meters The 100BASE-T1 MediaConverter is a physical layer changer. It is independent from transmitted protocol sent on the 100BASE-T1.
  • Page 16: List Of Figures

    7 LIST OF FIGURES Figure 1-1: 100BASE-T1 MediaConverter_BCM .............. 3 Figure 1-2 Copy of RoHS Certificate of Compliance ............7 Figure 2-1: Label of 100BASE-T1 MediaConverter_BCM ..........9 Figure 4-1: Example for use case ................... 13 Figure 5-1: 100BASE-T1 filter for HW v3.0 and v3.0a ........... 14 Figure 5-2: 100BASE-T1 filter for HW v2.0 ..............
  • Page 17: Changelog

    July 2020 1.1.4 of Technica Engineering’s Products 1.1.5 Added information on General Design Rules for the Power Supply of Technica Engineering’s Products Warranty and Safety Information updated RoHS Certificate of Compliance added Declaration of conformity added 100BASE-T1 MediaConverter_BCM User Manual...
  • Page 18: Contact

    9 CONTACT If you have any questions regarding this product, please feel free to contact us: Technica Engineering GmbH Leopoldstr. 236 80807 München Germany Technical support: support@technica-engineering.de General information: Info@technica-engineering.de Most current user manuals and product information: https://technica-engineering.de/ 100BASE-T1 MediaConverter_BCM User Manual...
  • Page 19: Declaration Of Conformity

    Čeština engineering.de/produkt/100base-t1- mediaconverter-bcm/ Tímto Technica Engineering GmbH prohlašuje, že produkt 100BASE-T1 MediaConverter BCM Español (TE-1000), souladu směrnicí 2014/30/EU. Úplné znění EU prohlášení o Por la presente, Technica Engineering GmbH shodě je k dispozici na této internetové...
  • Page 20 EUconformiteitsverklaring worden https://technica- geraadpleegd op het volgende internetadres: engineering.de/produkt/100base-t1- https://technica- mediaconverter-bcm/ engineering.de/produkt/100base-t1- mediaconverter-bcm/ Latviešu Polski Ar šo Technica Engineering GmbH deklarē, ka produkts 100BASE-T1 MediaConverter BCM Technica Engineering GmbH niniejszym (TE-1000), atbilst Direktīvai 2014/30/ES. Pilns oświadcza, że produkt 100BASE-T1 ES atbilstības deklarācijas teksts ir pieejams MediaConverter BCM (TE-1000), jest zgodny z šādā...
  • Page 21 Slovensko Slovensky Technica Engineering GmbH potrjuje, da je Technica Engineering GmbH týmto vyhlasuje, izdelek 100BASE-T1 MediaConverter BCM že produkt 100BASE-T1 MediaConverter BCM (TE-1000), skladen z irektivo 2014/30/EU. (TE-1000) , je v slade so smernicou Celotno besedilo izjave EU o skladnosti je na 2014/30/EÚ.

This manual is also suitable for:

Te-1000100base-t1

Table of Contents