Installation Requirements

Proper installation/ducting is
extremely important to ensure
maximum performance. Use a qualified
and trained installer.
DUCTING
• Check with a qualified and
trained installer or local codes
for makeup air requirements,
if any.
• Max. duct run
o For 300 – 1,200 CFM—50'
(15.2 m)
o For 1,500 CFM—75'
(22.9 m)
Note: All CFMs are based on tests with 0.1 static pressure. Without applying static pressure (some brands do not), CFM could be
greatly overstated.
Model
Ventilator Kits
Interior
VWH2448
VIV300/600
VWH3048
VIV300/600/1200*
VWH3648
VIV300/600/1200*
VWH4248
VIV600/1200*
VWH4848
VIV1200*
VWH5448
VIV1200*
VWH6048
VIV1200*
VWH6648
VIV1200*
VWH3678
VIV300/600/1200*
VWH4878
VIV1200*
VWH6078
VIV1200*
VCWH3048
DIV300/600
VCWH3648
DIV300/600*
VCWH4248
DIV600*
VCWH4848
DIV1200*
VCWH5448
DIV1200*
VCWH6048
DIV1200*
VCWH6648
DIV1200*
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs.
Note: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-wire with ground. An interior-
or exterior-power ventilator kit must be purchased for installation with all 18"H. hoods.
P L A N N I N G A N D D E S I G N G U I D E
V I K I N G R A N G E . C O M
Wall Hood

UTILITY REQUIREMENTS

o Duct run length is for
general reference only;
always use a qualified and
trained installer.
o Straight runs and gradual
turns are best; for example,
each 90° elbow is equivalent
to 5' – 10' (1.52 –
3.05 cm) of straight run.
• 7" round duct for 300 – 600
CFM; 10" for 900 – 1500 CFM
o Never use flexible duct; it
creates back pressure/air
turbulence and greatly
reduces performance.
Exterior
Interior
VEV900/1200*
7" (17.8 cm)
VEV900/1200*
7"(17.8 cm)/10" (25.4 cm)
VEV900/1200*
7"(17.8 cm)/10" (25.4 cm)
VEV900/1200*
7"(17.8 cm)/10" (25.4 cm)
VEV1200/1500**
10" (25.4 cm)
VEV1200/1500**
10" (25.4 cm)
VEV1200/1500**
10" (25.4 cm)
VEV1200/1500**
10" (25.4 cm)
VEV900/1200*
7"(17.8 cm)/10" (25.4 cm)
VEV1200/1500**
10" (25.4 cm)
VEV1200/1500**
10" (25.4 cm)
DEV900/1200*
7" (17.8 cm)
DEV900/1200*
7" (17.8 cm)
DEV900/1200*
7" (17.8 cm)
DEV1200/1500*
10" (25.4 cm)
DEV1200/1500
10" (25.4 cm)
DEV1200/1500
10" (25.4 cm)
DEV1200/1500
10" (25.4 cm)
1 - 8 8 8 - V I K I N G 1
VENTILATION
Professional Built-In 18"H.
Wall Hood/Chimney Wall Hood
Chimney Wall Hood
GAS
Not applicable
ELECTRICAL
• Hardwire direct with two-wire
with ground
• 120 VAC/60 Hz
• Max. amp usage (rating
includes rec. ventilator kit
rating)
PLUMBING
Not applicable
Duct Size
Exterior
Interior
10" (25.4 cm)
5.0/6.2
10" (25.4 cm)
5.0/6.2/8.7
10" (25.4 cm)
5.0/6.2/8.7
10" (25.4 cm)
6.2/8.7
10" (25.4 cm)
10" (25.4 cm)
10" (25.4 cm)
10" (25.4 cm)
10" (25.4 cm)
5.0/6.2/8.7
10" (25.4 cm)
10" (25.4 cm)
10" (25.4 cm)
3.9/6.0
10" (25.4 cm)
3.9/6.0
10" (25.4 cm)
10" (25.4 cm)
10" (25.4 cm)
10" (25.4 cm)
10" (25.4 cm)
© 2 0 0 7 V R C — INFORMATION SUBJECT TO CHANGE
Max. Amps
Exterior
8.7/6.1
8.7/6.1
8.7/6.1
8.7/6.1
11.1
8.4/9.1
11.1
8.4/9.1
11.5
8.8/9.5
11.5
8.8./9.5
8.7/6.1
11.1
8.4/9.1
11.5
8.8/9.5
8.7/6.0
8.7/6.0
6.0
8.7/6.1
11.5
8.5/9.2
11.5
8.5/9.2
11.9
8.9/9.7
11.9
8.9/9.7
R E L E A S E D 1 2 / 1 / 0 7