Download Print this page

Installation Requirements; Utility Requirements - Viking DCWH Specification Sheet

Built-in classic chimney wall hood— standard, w/ledge, & ledgeless
Hide thumbs Also See for DCWH:

Advertisement

Installation Requirements

DCWH Designer
Chimney Wall Hood
Proper installation/ducting is extremely
important to ensure maximum
performance. Use a qualified and
trained installer.
VENTILATION
• Check with a qualified and
trained installer or local codes
for makeup air requirements, if
any.
• Max. duct run
o For 300 – 1,200 CFM—50'
(15.2 m)
o For 1,500 CFM—75' (22.9 m)
o Duct run length is for general
reference only; always use a
qualified and trained installer.
Note: All CFMs are based on tests with 0.1 static pressure. Without applying static pressure (some brands do not), CFM could be greatly
overstated.
Model
Ventilator kits
Interior
DCWH3042
DIV300/DIV440
DCWH3644
DIV300/DIV600*
DCWH4244
DIV600
DCWH4844
DIV1200*
DCWL3342
DIV300/DIV440
DCWL3944
DIV300/DIV600*
DCWL4544
DIV600
DCWL5144
DIV1200
DCWN3042
DIV300/DIV440
DCWN3644
DIV300/DIV600*
DCWN4244
DIV600
DCWN4844
DIV1200*
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs.
Note: Maximum amp rating for hoods includes recommended ventilator kit rating. All products must be hard wired with two-wire ground. An interior- or
exterior-power ventilator kit must be purchased for installation with all 18"H. hoods.
P L A N N I N G A N D D E S I G N G U I D E
V I K I N G R A N G E . C O M
Built-In Classic Chimney Wall Hood—
DCWL Designer
Chimney Wall Hood
w/Ledge

UTILITY REQUIREMENTS

o Straight runs and gradual
turns are best; for example,
each 90" elbow is equivalent
to 5' – 10' (1.52 – 3.05 cm) of
straight run.
• 7' round duct for 300 – 600
CFM; 10' for 900 – 1500 CFM
o Never use flexible duct; it
creates back pressure/air
turbulence and greatly
reduces performance.
GAS
Not applicable
Exterior
Interior
DEV900/DEV1200
7" (17.8 cm)
DEV900/DEV1200*
7" (17.8 cm)
DEV900/DEV1200*
7" (17.8 cm)
DEV1200/DEV1500**
10" (25.4 cm)
DEV900/DEV1200
7" (17.8 cm)
DEV900/DEV1200*
7" (17.8 cm)
DEV900/DEV1200*
7" (17.8 cm)
DEV1200/DEV1500**
10" (25.4 cm)
DEV900/DEV1200
7" (17.8 cm)
DEV900/DEV1200*
7" (17.8 cm)
DEV900/DEV1200*
7" (17.8 cm)
DEV1200/DEV1500**
10" (25.4 cm)
1 - 8 8 8 - V I K I N G 1
VENTILATION
Standard, w/Ledge, & Ledgeless
Chimney Ledgeless
ELECTRICAL
• Hardwire direct with two-wire
• 120 VAC/60 Hz
• Max. amp usage (rating
PLUMBING
Not applicable
Duct size
Exterior
10" (25.4 cm)
10" (25.4 cm)
10" (25.4 cm)
10" (25.4 cm)
10" (25.4 cm)
10" (25.4 cm)
10" (25.4 cm)
10" (25.4 cm)
10" (25.4 cm)
10" (25.4 cm)
10" (25.4 cm)
10" (25.4 cm)
© 2 0 0 7 V R C — INFORMATION SUBJECT TO CHANGE
DCWN Designer
Wall Hood
with ground
includes rec. ventilator kit
rating)
Max. amps
Interior
Exterior
1.7/3.2
6.6/3.9
1.7/3.9
6.6/3.9
3.9
6.6/3.
7.3
4.3/5.1
1.7/3.2
6.6/3.9
1.7/3.9
6.6/3.9
3.9
6.6/3.9
7.3
4.3/5.1
1.7/3.2
6.6/3.9
1.7/3.9
6.6/3.9
3.9
6.6/3.9
7.3
4.3/5.1
R E L E A S E D 1 2 / 1 / 0 7

Advertisement

loading