combustion chamber pressure measured at connection 2). Refer
to the example in the adjacent figure.
TL
TR
0
LED
*
RMO
Burner calibration
A
A
*
Off
Yellow
For further details see pag. 25.
RL 70
kg/h
mbar
40
8.5
50
8.6
60
8.8
70
9.2
mbar = air pressure in 1) with zero pressure in 2)
With shutter 4) retracted (Fig. 8 pag. 12)
(1)
NOTE:
in order to facilitate adjustment of hex elements 2) and
4)(Fig. 21), use a 3 mm Allen key 5) (Fig. 21).
TL
LED
*
RMO
D3280
Green
21
GB
RL 100
RL 130
kg/h
mbar
kg/h
60
7.2
80
70
7.7
90
80
8.4
100
90
9.3
110
100
11.0
120
130
130
D700
Red
mbar
7
7.2
7.6
8.1
9.0
11.0
8.5
(1)
Tab. E
Fig. 22
D3281
Fig. 23
20111051