Siemens SINAMICS S120 Manual page 19

Safety integrated extended functions, fail-safe drives, controlling the cu320 from a tm54f and f-cpu
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

SINAMICS S120 Fail-Safe Drives
F-DIs of the F-CPU
Emergency Stop pushbutton
F-DI0/F-DI4
Reset button
F-DI1
Protective door_1 open
F-DI2/F-DI6
Protective door_1 closed
Protective door_2 open
F-DI3/F-DI7
Protective door_2 closed
The drives can only be operated when the infeed is powered-up and the
Note
DC link is charged.
I DT Safety Integrated
SS1 in both drives
Acknowledges the Emergency Stop
function
Acknowledges an Internal Event in
TM54F
SLS_door_1 – 0 signal; drive_1
operates at a low speed.
SLS in drive 1 activated
SLS_door_1 – 1 signal; drive_1
operates at the normal speed.
SLS in drive 1 not activated.
SLS_door_2; drive_2 operates at a
low speed.
SLS in drive_2 activated
SLS_door_2 – 1 signal; drive_2
operates at the normal speed.
SLS in drive_2 not activated.