Function ...................................................................... 2
Symbols and Safety ................................................ 2
Danger Signs ............................................................. 2
Usage As Per Specification ................................... 3
Basic Specifications................................................. 3
Removing/Closing the Cover .............................. 4
Wiring Diagram ........................................................ 4
High Voltage Power Supply ................................. 4
Electric Supply .......................................................... 5
DIP Switch Functions/Settings ........................... 6
ILEA A/B Series electric actuators

TABLE OF CONTENTS

Manual Operation ................................................... 6
Actuator Parts Identifications ............................. 7
Actuator Removal Instruction ............................. 7
Removing/Replacing of Actuator ...................... 8
Operator Push Buttons .......................................... 9
Operating Direction .............................................10
Status Display .........................................................10
Commissioning/Operation ......................... 11-12
Maintenance ...........................................................12
Decommissioning/Disposal ..............................12
Usage and Storage ................................................13
ILEA-A
ILEA-B
ILEA-A/B_IOM_NoRev_1118
92500136 No Rev
xx
xx

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ARIA Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Warren Controls ARIA Series

  • Page 1: Table Of Contents

    ILEA A/B Series electric actuators ILEA-A ILEA-B TABLE OF CONTENTS Function ..............2 Manual Operation ........... 6 Symbols and Safety ..........2 Actuator Parts Identifications ......7 Danger Signs ............. 2 Actuator Removal Instruction ......7 Usage As Per Specification ........3 Removing/Replacing of Actuator ......
  • Page 2: Function

    FUNCTION The ARIA Series actuators are designed as Spring-Fail-Safe upon spindle nut transmits the input torque into an axial thrust force Loss of- Power, or Loss-of-Signal. The actuator is mounted onto via a spindle. The linear stroke is transmitted to the valve spindle the control valve via pillars and mounting base and attached via by a coupling piece.
  • Page 3: Usage As Per Specification

    USAGE AS PER SPECIFICATION • ARIA Series actuators are exclusively designed to be used as • Read this document in its entirety as special precautions electric valve actuators for rising stem globe control valves. need to be taken before mounting and adjusting the actuator...
  • Page 4: Removing/Closing The Cover

    REMOVING / CLOSING THE COVER Open: Loosen the screws by using a screwdriver and unscrew them entirely out of the gear casing. The screws are captivated. Open the cover only in a dry environment. Close: Put the cover on the gear casing and press down slightly. Tighten the screws gently and then crosswise for even tightening.
  • Page 5: Electric Supply

    ARIA Series electric actuators do not have an internal electrical power Please protect all of the power supply and control cables in front of the terminals mechanically by using suitable measures against unintentional loosening.
  • Page 6: Dip Switch Functions/Settings

    POSITION SWITCH SET UP (OPTIONAL) FAULT RELAY DESCRIPTION 2600 Emrick Blvd • Bethlehem, PA 18020 • USA • 800-922-0085 • www.warrencontrols.com...
  • Page 7: Actuator Removal Instruction

    DEFAULT PARAMETERS SOFTWARE SET UP ILEA-A/B_IOM_NoRev_1118...
  • Page 8: Actuator Parts Identifications

    ACTUATOR PARTS IDENTIFICATION Pillar Coupling Clamping Screws Coupling Nut for Spring Pack Valve Stem Locking Nut Yoke Lock Nut Bracket Pillar Nut 2600 Emrick Blvd • Bethlehem, PA 18020 • USA • 800-922-0085 • www.warrencontrols.com...
  • Page 9: Operator Push Buttons

    ACTUATOR REMOVAL/REPLACEMENT INSTRUCTIONS ILEA-A/B_IOM_NoRev_1118...
  • Page 10: Operating Direction

    ACTUATOR COMMISSIONING & STATUS LED’S Electric supply for 3-phase AC ILEA actuators are commissioned at the factory when The actuator can only be commissioned when correctly mounted to a control Valve. mounted to a valve and with at least one cut off set to “force/ torque.
  • Page 11: Commissioning/Operation

    ILEA-A/B_IOM_NoRev_1118...
  • Page 12: Maintenance

    TRACING FAULTS CHARTS (A/B ONLY) 18. Tracing faults    Red LED  Green LED                             Status  Probable reasons  Possible remedy           x           x  Actuator does not respond, both  1) No supply voltage applied  1) Check mains supply  LEDs are off  2) The applied voltage does  2) Apply correct supply  not match the actuator  voltage  voltage on the tag plate          ...
  • Page 13: Usage And Storage

    TRACING FAULTS CHARTS (A/B ONLY) Red LED  Green LED                      Faults within the actuator’s  Probable reasons  Possible remedy  environment        x           x      Actuator drives into a preset  1) Signal is applied to the  1) Disconnect the signal   position  binary fail‐safe input  2) Check supply voltage  2) Supply voltage failure on  actuators with optional  PSCP        x ...
  • Page 14 2600 Emrick Blvd • Bethlehem, PA 18020 • USA • 800-922-0085 • www.warrencontrols.com...
  • Page 15 ILEA-A/B_IOM_NoRev_1118...
  • Page 16 ILEA-A/B_IOM_NoRev_1018 92500136 No Rev 2600 EMRICK BLVD • BETHLEHEM, PA 18020 • USA •800-922-0085 • WWW.WARRENCONTROLS.COM DEPENDABLE, RUGGED, PRECISION CONTROL VALVES AND ACCESSORIES...