ALIGNAIENT OF TRANSMITTER
1.
Test Equipment Required
Oscilloscope (5QMHz)
RF Power Meter
50 ohc Load
2.
Aligament Procedure
PRESET ТО
STEP
NO Modulation
1
CH:
19
Mode: AM
2
' Same as STEP 1
Same as Step 1
3
4
Saae as Step 1
5
Mode : FM
CH: 1
3.
Test Equipment Connection
Form: ADJ04-M-3
DC Power Supply
Frequency Counter
Audio OscilLator
ADJUSTMENT
LII, L14
Connect Oscilloscope to T?-3(R46).
and L15
Adjust for maximum reading on
Oscilloscope.
L10, Lll
Connect RF Power Meter to ANT Jack
and L7
(J501).
on RF Power Meter.
Adjust foc 4.0 W reading on
L7
RF Power Meter.
Adjust the needle to blank zone
VR3
betueen Green and Red on Trans-
ceiver' s Meter.
VR601
Set Mic Input to 30mV.
Connect Deviation Meter to ANT Jack.
Adjust for 3.5kHz Deviation.
AC Volt ceter
Deviation Meter
REMARKS
Adjust for maximum reading
F R E O . C O U N T