Download Print this page

Alignment Procedures - PRESIDENT Randy II P Service Manual

Hide thumbs Also See for Randy II P:

Advertisement

ALIGNMENT PROCEDURES

This software do not need to install. Double-click the
DaAd Debug(A/D Debug)
Get the current battery voltage
Get the current SQ RSSI
Get the current SQ Noise
1. Battery voltage setting:No need to use this function, we've already set, so pls do not alignment this
parameter.
2. RSSI setting:There are 7 RSSI levels should be alignment. Every level has its own RF LEV (see as
bellow).
RSSI Level
AM/FM
RF LEV
Procedure: Set the "RF LEV" on equipment to -123dBm,and the select the RSSI level "0". If the channel
is at FM, choose "FM" in the software, then press Get A/D" of SQ Rssi,, then press "Set File" to store the
setting. After that, continue to set the RSSI Level "1" and the rest level. When all of the 7 RSSI levels set,
switch the radio to AM, then using the same way to set RSSI Level at AM. (See as bellow)
need
0
1
-123
-120
Page 12/42
icon.
RSSI & Noise level
4
7
-109
-97
To get the value that have been
written in the radio.
To store the new set value.
10
13
-85
-73
15
-48

Advertisement

loading

This manual is also suitable for:

Randy ii mXh9006e.randy ii pXh9006e.randy ii mStabo xh9006e