Download Print this page

Specifications - ADC Category 5e Specification Sheet

Basic structured cabling systems

Advertisement

Specifications

Environment for use:
Operating Temperature Range:
Transmission performance:
Number of plug insertion cycles:
Insulation Displacement Contact
Wire diameter for solid copper conductors:
110 Interface Resistance:
Contact Resistance:
Number of Wire Re-terminations:
Electrical Rating of Complete Assembly at 25 °C (77 ºF) and 50%RH
Ringing Voltage Rating:
Current Rating:
Insulation Resistance:
Safety Rating:
O r d e r i n g I n f o r m a t i o n
Description
110 Type Blocks
100 pair block – 4 pair increments
100 pair block – 5 pair increments
300 pair block – 4 pair increments
300 pair block – 5 pair increments
110 Type Block 19" Rack Mount Kits
100 pair rack mountable block with 5-Pair C-Clips with 19" Mounting Bracket with
labels and label holders
300 pair rack mountable block with 5-Pair C-Clips with 19" Mounting Bracket with
labels and label holders
Accessories
4-pair C-Clip (pack of 24pcs)
5-pair C-Clip (pack of 20pcs)
Cable Trough
Jumper Trough for 19" equipment rack
Website: www.adc.com
From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080
Fax: +1-952-917-3237 • For a listing of ADC's global sales office locations, please refer to our website.
ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101
Specifications published here are current as of the date of publication of this document. Because we are continuously
improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may
verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc.
views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features
contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer
101844AE 8/08 Revision © 2008, 2006, 2005 ADC Telecommunications, Inc. All Rights Reserved
Indoors, in dry, closed room
-10° to 60 °C (14º to 43 ºF)
≥TIA/EIA 568-B.2 Category 5e
≥750
22-26 AWG (0.40 to 0.65 mm)
≤20mΩ
≤1mΩ
≥100
≤150V AC
<2A
≥100 MΩ at 500V DC
UL 1863
Catalog Number
ECO BLOCK 100-4L
ECO BLOCK 100-5L
ECO BLOCK 300-4L
ECO BLOCK 300-5L
ECO-BLOCKRM-100
ECO-BLOCKRM-300
ECO BLOCK-4
ECO BLOCK-5
ECO TROUGH-L
ECO-BLOCKRMT

Advertisement