Summary of Contents for Cervis SmaRT EBU-xH24XF Series

  • Page 1 ™ EBU-xH24XF Base Unit User Manual U109.0.0 2018 Cervis, Inc.
  • Page 2 SmaRT EBU-xH24XF Base Unit This document is the property of Cervis, Inc. and cannot be copied, modified, e-mailed, or reproduced without the express prior written consent of Cervis, Inc. Cervis, Inc. reserves the right to change this manual or edit, delete, or modify any information without prior notification.
  • Page 3: Table Of Contents

    User Manual Table of Contents List of Figures ..........................i List of Tables ..........................i Cervis Inc. Safety Precautions ....................ii 1.0 SmaRT EBU-xH24XF Base Unit Introduction ..............1 2.0 Features ..........................1 3.0 EBU-xH24XF LEDs ....................... 2 4.0 EBU-xH24XF Mounting ......................3 5.0 EBU-xH24XF Wiring ......................
  • Page 4: Cervis Inc. Safety Precautions

    SmaRT EBU-xH24XF Base Unit Cervis Inc. Safety Precautions  Read and follow all instructions.  Failure to abide by Safety Precautions may result in equipment failure, loss of authority to operate the equipment, and personal injury.  Use and maintain proper wiring. Follow equipment manufacturer instructions.
  • Page 5: Smart Ebu-Xh24Xf Base Unit Introduction

    User Manual 1.0 SmaRT EBU-xH24XF Base Unit Introduction The versatile EBU-xH24XF base units feature an H-Bridge, sixteen FET (field effect transistor) high-side switching outputs or switch-to-ground digital inputs, two Form C relays, and CAN Bus control capability. Using Direct Sequence Spread Spectrum (DSSS) wireless technology at 900MHz or 2.4GHz, the base unit provides a robust link with a SmaRT handheld remote in congested radio environments.
  • Page 6: Ebu-Xh24Xf Leds

    SmaRT EBU-xH24XF Base Unit 3.0 EBU-xH24XF LEDs The EBU-xH24XF has five status/system LEDs that indicate the current state of the active base unit and can be used for troubleshooting when necessary. These LEDs are defined in Table 1. Table 1. EBU-xH24XF LEDs Name Color Indication...
  • Page 7: Ebu-Xh24Xf Mounting

    6 inch flying leads for wiring to appropriate outputs. Table 3 defines the cable plug pins, the pin type, and the match to the numbered flying lead. For instance: Pin 1 of Connector A is described as 1:M1: 1, where 1(connector pin): M1 (the defined 2018 Cervis, Inc.
  • Page 8: Figure 3. Ebu-Xh24Xf Base Unit And Harness Hn-1026 Pinouts

    SmaRT EBU-xH24XF Base Unit output):, and 1 (numbered flying lead). Appendix E Table 10 lists available cable harness options. Table 3. HN-1026 and HN-1027 Cable Harnesses Pins to Flying Leads Assignments Conn. Pins to Leads Assignments (Pin: Type: Lead) 1: M1: 1 2: M2: 2 3: M3: 3 4: M4: 4...
  • Page 9: Figure 4. Ebu-Xh24Xf Base Unit And Harness Hn-1027 Pinouts

    User Manual Figure 4. EBU-xH24XF Base Unit and Harness HN-1027 Pinouts 2018 Cervis, Inc.
  • Page 10: Individual Wiring Harness Models Hn-1016 To Hn-1019

    SmaRT EBU-xH24XF Base Unit 5.2 Individual Wiring Harness Models HN-1016 to HN-1019 Individual wiring harness models HN-1016, HN-1017, HN-1018, and HN-1019 are illustrated and defined in the following four tables and figures. Each have pins (1-12) that directly relate to the individually numbered leads (1-12) of the each cable, though the output assignments of each cable are unique to the specific cable as shown in the following four tables.
  • Page 11: Figure 7. Ebu-Xh24Xf Base Unit Harness Hn-1018 (Socket B)

    1: M17 NC 2: M17 COM 3: M17 NO 4: M18 NC 5: M18 COM 6: M18 NO 7: M19 8: M20 9: +VIN 10: +VIN 11: GND 12: GND Figure 8. EBU-xH24XF Base Unit Harness HN-1019 (Socket D) 2018 Cervis, Inc.
  • Page 12: Smart Handheld & Base Unit Remote Association

    SmaRT EBU-xH24XF Base Unit 6.0 SmaRT Handheld & Base Unit Remote Association A SmaRT remote control system must have communications between the SmaRT handheld control unit and the EBU-xH24XF base unit is set up at the factory using an Associate process prior to shipping the system.
  • Page 13: Smart Ebu-Xh24Xf Specifications

    Plug B (Black) 5: RS232RX 6: M21 7: M22 8: M23 Pins 1-12 9: M24 10: +VIN 11: GND 12: GND   Note: EBU-xH24XF-CAN units are internally terminated at 1.2k .Termination can be removed at the factory. 2018 Cervis, Inc.
  • Page 14: Appendix A: Exposure To Radio Frequency Energy

    EXT-10-200 3 ft. antenna cable (J5-07) and external antenna (BB3-06) EXT-3-900 3 ft. antenna cable (J5-07) and external antenna (BB3-07) EXT-3-200  Note: Only the antenna recommended by Cervis, Inc. is to be used with the SmaRT base unit. U109.0.0...
  • Page 15: Appendix D: Ebu-Xh24Xf Model Specifications

    Individually numbered 6 inch flying leads One 12-pin connector; 12 wire; 90 inch total length HN-1018 BLACK Individually numbered 6 inch flying leads One 12-pin connector; 12 wire; 90 inch total length HN-1019 BROWN Individually numbered 6 inch flying leads 2018 Cervis, Inc.