  • Page 1 ™ 8.0. ™ SmaRT BU-xH6R Base Unit Manual U078.2.3-SmaRTxH6R_BU-R 2019 Cervis, Inc.
  • Page 2: Fcc Statements

    RoHS Compliance Statement Cervis, Inc. complies with the requirements of Restriction of Hazardous Substances (RoHS/WEEE) Specification based on in-house practice and declaration of compliance from our vendors. For additional information concerning RoHS compliance, please contact Cervis, Inc. at: CERVIS, Inc.
  • Page 3: Table Of Contents

    List of Figures ..........................ii List of Tables ..........................ii Cervis, Inc. Safety Precautions ....................iv 1.0 SmaRT BU-xH6R Base Unit ....................1 1.1 Base Unit Installation ....................... 3 1.2 Optional Antenna Extension Installation ............... 5 1.3 BU-xH6R Wiring ........................ 6 1.4 External Protection Devices for Relay Contacts ............
  • Page 4 Table 2. Base Unit Output LED Interlock Indications ..............7 Table 3. SmaRT BU-xH6R Specifications ..................9 Table 4. SmaRT BU-xH6R Variations ..................10 Table 5. BU-xH6R Troubleshooting Hints ................. 12 Table 6. Compatible BU-xH6R (BU- xH6R-EXT) External Antenna Details ......14 Table 7.
  • Page 5 Snubber (Snubber Circuit) Electrical circuit used to suppress electrical spikes (transients) by diverting excess current around the protected device. RS-232 Low-speed serial interface used for base unit configuration. 2019 Cervis, Inc.
  • Page 6: Cervis, Inc. Safety Precautions

    SmaRT BU-xH6R Cervis, Inc. Safety Precautions  Read and follow all instructions.  Failure to abide by Safety Precautions may cause equipment failure, loss of authority to operate the equipment, and personal injury.  Use and maintain proper wiring. Follow equipment manufacturer instructions.
  • Page 7: Smart Bu-Xh6R Base Unit

    Base Unit Manual 1.0 SmaRT BU-xH6R Base Unit The SmaRT BU-xH6R Base Unit features six Form C relay outputs. Each Form C relay contact can switch up to 8 amperes at 250 VAC or VDC. Using Direct Sequence Spread Spectrum (DSSS) wireless technology at 900 MHz or 2.4 GHz, the base unit robustly links with a handheld...
  • Page 8 SmaRT BU-xH6R BU-xH6R Base Unit Features (See Table 4 for a complete listing.)  Capable of communicating to up to eight SmaRT handheld remote control units  License-free frequency, Direct Sequence Spread Spectrum (DSSS) technology for 900 MHz @ 10mW or 2.4 GHz @ 100 mW radio frequency (RF) power ...
  • Page 9: Base Unit Installation

    During installation, make sure the machine that the base unit will be attached to is disabled. Use the configuration diagrams supplied by Cervis, Inc. to guide you in mounting the base unit and connecting your wiring harness cables. Base unit mounting is left much to your discretion with the following guidelines: ...
  • Page 10: Figure 3. 2.4Ghz And 900Mhz External Antenna Mounting Dimensions

    SmaRT BU-xH6R 2.4GHz 115mm (4.57") 900MHz 183mm (7.2") 7.4mm (0.29") dia. 118mm (4.7") Figure 3. 2.4GHz and 900MHz External Antenna Mounting Dimensions U078.2.3-SmaRTxH6R_BU-R...
  • Page 11: Optional Antenna Extension Installation

    2. Rethread the nut to secure the ferrule to the device. 3. Attach cable extension to the BU-xH6R. 4. Attach the antenna to the extension ferrule. External Antenna BB3-07 3' Extension Cable J5-07 1 and 2 RP-TNC Connecters Figure 4. Antenna Extension Kit Installation 2019 Cervis, Inc.
  • Page 12: Bu-Xh6R Wiring

    SmaRT BU-xH6R 1.3 BU-xH6R Wiring Figure 5. Dual Connectors/Pin Numbers (enhanced) If the base unit supply voltage drops below a minimum volt level—even momentarily—the unit will reset. Minimum supply voltages are:  7VDC for a BU-xH6R-xxx-LVD  7VAC for a BU-xH6R-xxx-LVA Caution ...
  • Page 13: External Protection Devices For Relay Contacts

    R-C snubbers—may be necessary, depending on the application and whether the switched circuits are AC or DC. When using contactors or solenoids with SmaRT systems, Cervis, Inc. advises using external protective devices by connecting them across the coils as shown in the examples below using MOVs.
  • Page 14 SmaRT BU-xH6R Handheld Remote Command BU-xH6R Result Momentary Action Press and hold function Operating Mode Interlock prevents K3 and K4 output corresponding Output 3 and Operating Mode Interlock activity. Output LED is unlit. Output 4 Press and hold function Output K5 active; Output LED lights and remains lit...
  • Page 15: Smart Bu-Xh6R Specifications

    Base Unit 2.0 SmaRT BU-xH6R Specifications Table 3. SmaRT BU-xH6R Specifications Item Description Power Operating Power 5W max. RF power 10mW @ 900MHz; 100mW @ 2.4GHz BU-xH6R-xxx-HVU 100–240VAC @ 47–440Hz, or 120–370VDC BU-xH6R-xxx-LVD 7–32VDC BU-xH6R-xxx-LVA 7–28VAC Environment Operating temp. -25°C to 60°C (-13°F to 140°F) Storage temp.
  • Page 16: Smart Bu-Xh6R Variations

    SmaRT BU-xH6R 3.0 SmaRT BU-xH6R Variations Common Features: No Display; Channel Type are all Form C Relays; Number of channels each is 6. Table 4. SmaRT BU-xH6R Variations Serial SmaRT Model Freq RF Pwr Input Pwr Antenna Port Connect BU-9H6R-INT-LVD...
  • Page 17 SmaRT Model Freq RF Pwr Input Pwr Antenna Port Connect BU-2H6R-EXT-LVA-NOS-CAN 2.4GHz 100mW 7–28VAC External BU-2H6R-EXT-HVU 2.4GHz 100mW 100–240VAC External RS-232 BU-2H6R-EXT-HVU-CAN 2.4GHz 100mW 100–240VAC External BU-2H6R-EXT-HVU-NOS 2.4GHz 100mW 100–240VAC External RS-232 BU-2H6R-EXT-HVU-NOS-CAN 2.4GHz 100mW 100–240VAC External 2019 Cervis, Inc.
  • Page 18: Bu-Xh6R Troubleshooting Hints

    Is input power present? Power LED not Indicates internal fuse blown.  Check input power polarity active for VDC.  Power LED Red or Contact Cervis, Inc. service Indicates an internal component failure. Green department.  Check for obstructions preventing line-of-sight transmission. ...
  • Page 19 Be aware that even if the handheld and base unit diagnostic LEDs do not indicate a problem, one may be present and further troubleshooting steps may be needed. If a problem is found, do not operate the SmaRT System until the problem is resolved. 2019 Cervis, Inc.
  • Page 20: Bu-Xh6R (Bu-Xh6R-Ext) Antenna And Cable List

    EXT-10-900 3 ft. antenna cable (J5-07) and external antenna (BB3-06) EXT-3-900  Note: Only use the antenna recommended by Cervis, Inc. with the SmaRT base unit. Table 7. Compatible BU-xH6R P1 and P2 Cables Wiring Harness Part Number Cable P1...
  • Page 21: Appendix A: Exposure To Radio Frequency Energy

    This process is called “Association.” Handheld remote and base unit communications are established at Cervis, Inc. before shipping when systems are ordered. However, it may be necessary to establish or re-establish communication between a remote and a base unit at some point.
  • Page 22: C1: Bu-Xh6R/Pto Remote Communication

    SmaRT BU-xH6R C1: BU-xH6R/PTO Remote Communication To Associate Before attempting to associate, the base unit and handheld must be OFF. Base unit and SmaRT 2-, 4-, and 6-button handheld association is established using the following steps: 1. Remove power from the base unit and turn off (time out) the handheld device.
  • Page 23 Once the process is complete, all LEDs light briefly and then go out. 9. Release the Dissociate button. The SmaRT base unit will not communicate with any handheld remote units. A handheld remote must use the Association Procedure (above) to re-establish a communication link with the base unit. 2019 Cervis, Inc.
  • Page 24: C2: Bu-Xh6R/Cb Remote Communication

    SmaRT BU-xH6R C2: BU-xH6R/CB Remote Communication To prevent inadvertent machine movement, be sure to Caution remove power from the Base Unit before attempting to Associate or Dissociate. Before starting the Association process, turn OFF the console box remote and remove power from the base unit.
  • Page 25 Base Unit  Note: Be aware that all remote associations to the base unit are now broken. 2019 Cervis, Inc.
  • Page 26: C3: Bu-Xh6R/Mcb Remote Communication

    SmaRT BU-xH6R C3: BU-xH6R/MCB Remote Communication To prevent inadvertent machine movement, be sure to Caution remove power from the Base Unit before attempting to Associate or Dissociate. To Associate (see Figure 11) The MCB remote must be OFF and the base unit must have power removed before starting the Association process.
  • Page 27: Figure 11. Mcb Switch Actuation For Associate And Dissociate

    4. Observe the LEDs. When TX begins to blink, power up the base unit while continuing to hold switch SW1 and the Power button. When all four LEDs light solid, release SW1 and the pushbutton.  Note: Be aware that all remote associations to the base unit are now broken. 2019 Cervis, Inc.
  • Page 28: C4: Bu-Xh6R/Pg Remote Communication

    SmaRT BU-xH6R C4: BU-xH6R/PG Remote Communication To prevent inadvertent machine movement, be sure to Caution remove power from the Base Unit before attempting to Associate or Dissociate. To Associate (See Figure 12). The PG remote must be OFF, and the base unit must have power removed before starting the Association process.
  • Page 29: C5: Bu-Xh6R/Xx-218 Remote Communication

    3. Press and hold button 2, then press and hold button 1. Hold both buttons simultaneously. 4. Wait until the amber LED2 goes out. Release the two buttons being held. 5. Press and release button B16. The GREEN LED1 and the RED LED3 turn ON. 6. Power up the base unit. 2019 Cervis, Inc.
  • Page 30: Figure 14. Xx-218 Dissociate Mode

    SmaRT BU-xH6R If the Association is successful, the AMBER LED2 will flash. If communications are not established following the Associate procedure, repeat until communication between the handheld and base unit is achieved. To Dissociate (see Figure 14) Figure 14. XX-218 Dissociate Mode ...
  • Page 31 Base Unit www.cervisinc.com Visit our Web site at: 2019 Cervis, Inc. All rights reserved. Content is subject to change without notice. 2019 Cervis, Inc.