Cervis SmaRT BU-xH8D Series Manual

Base unit 900 mhz and 2.4ghz

Advertisement

Quick Links

SmaRT BU-xH8D
Base Unit Family
900MHz and 2.4GHz Manual
U088.4.4-SmaRT_BU-xH8D
2019 Cervis, Inc.

Advertisement

Table of Contents
loading

Summary of Contents for Cervis SmaRT BU-xH8D Series

  • Page 1 ™ SmaRT BU-xH8D Base Unit Family 900MHz and 2.4GHz Manual U088.4.4-SmaRT_BU-xH8D 2019 Cervis, Inc.
  • Page 2 RoHS Compliance Statement Cervis, Inc. complies with the requirements of Restriction of Hazardous Substances (RoHS/WEEE) Specification based on in-house practice and declaration of compliance from our vendors. For additional information concerning RoHS compliance, please contact Cervis, Inc. at: CERVIS, Inc.
  • Page 3: Table Of Contents

    900MHz and 2.4MHz Manual Table of Contents List of Figures ..........................ii List of Tables ..........................ii Cervis, Inc. Safety Precautions ....................iii Definitions/Notes ......................... iv 1.0 SmaRT BU-xH8D Base Unit ....................1 2.0 BU-xH8D Base Unit ......................2 2.1 Base Unit Installation ....................... 3 2.2 Base Unit Power .......................
  • Page 4 SmaRT BU-xH8D Base Unit Family List of Figures Figure 1. BU-xH8D External and Internal Antenna Base Units ..........1 Figure 2. BU-xH8D P1Twelve (12) Pin Connector ...............2 Figure 3. BU-xH8D Status LEDs ....................2 Figure 4. Base Unit Installation Dimensions................3 Figure 5. BU-xH8D with External Antenna and Extension Cable ..........4 Figure 6.
  • Page 5: Cervis, Inc. Safety Precautions

    900MHz and 2.4MHz Manual Cervis, Inc. Safety Precautions  Read and follow all instructions.  Failure to abide by Safety Precautions may cause equipment failure, loss of authority to operate the equipment, and personal injury.  Use and maintain proper wiring. Follow equipment manufacturer instructions.
  • Page 6: Definitions/Notes

    SmaRT BU-xH8D Base Unit Family Definitions/Notes Associate/Association SmaRT configuration method using a series of specific remote unit button presses to establish a communication link between a SmaRT handheld remote and a SmaRT base unit. DSSS Direct Sequence Spread Spectrum; an advanced wireless communication technology. Dissociate/Disassociate/Dissociation Dissolution of all established communication links between handhelds and a base unit.
  • Page 7: Smart Bu-Xh8D Base Unit

    1.0 SmaRT BU-xH8D Base Unit The BU-xH8D base units are the output/input modules of a SmaRT Remote Control System. A basic SmaRT control system consists of at least one Smart wireless remote transmitter, a BU- xH8D base unit, and the wiring harness that connects the base unit to the controlled apparatus. A single base unit can communicate with up to eight individual SmaRT handheld remote units, depending on remote control type.
  • Page 8: Bu-Xh8D Base Unit

    SmaRT BU-xH8D Base Unit Family 2.0 BU-xH8D Base Unit The SmaRT BU-xH8D base unit features eight FET, 2.5A (8A max total) high-side switching outputs/inputs capable of digital or pulse-width-modulation (PWM) control @ 30–200Hz. It accepts an input power operating voltage range from +7 to +28VDC. The base unit provides a robust link with a handheld remote in congested radio environments using Direct Sequence Spread Spectrum (DSSS) wireless technology broadcasting 900MHz @ 10mW and 2.4GHz @ 100mW.
  • Page 9: Base Unit Installation

    Disable the machine on which the base unit is to be attached before installation. Use the configuration diagrams supplied by Cervis, Inc. to guide you in mounting the base unit and connecting your wiring harness. Base unit mounting is left much to your discretion with the following guidelines: ...
  • Page 10: Base Unit Power

    SmaRT BU-xH8D Base Unit Family 2.2 Base Unit Power Power is supplied to the base unit though the harness cable. The cable attaches to the base unit P1 connector. Power can be removed from the base unit by disconnecting the 12-pin cable connector from the base unit P1 socket.
  • Page 11: Base Unit Cable And Field Wiring

    P1:4 P1:5 P1:6 P1:7 RS-232 TX CANH P1:8 RS-232 RX CANL P1:9 P1:10 P1:11 –VDC –VDC P1:12 Caution To protect against short circuits, make sure the ends of all unused wires are insulated when making your connections. 2019 Cervis, Inc.
  • Page 12: Bu-Xh8D Operation

    SmaRT PTO, DO, OO, pistol-grip, CB, and MCB remotes; or, with another SmaRT base unit. Each wireless remote used must Associate to establish communications with the base unit. Systems are associated at Cervis, Inc. before shipping. But, when necessary, the Associate procedure (see Appendix C) can be used to establish communications.
  • Page 13: Bu-Xh8D Base Unit Specifications

    PWM Range: 30Hz to 200Hz Analog (2) 0–10V/4–20mA input (M7 and M8 when chosen) (optional) 0–10V output (M7 and M8 when chosen)   Note: BU-xH8D-CAN units are internally terminated at 1.2K . Termination can be removed at the factory. 2019 Cervis, Inc.
  • Page 14: Bu-Xh8D (Bu-Xh8D-Ext) Antenna And Cable List

    10 ft. antenna cable (J5-02) and external antenna (BB3-06) EXT-10-900 3 ft. antenna cable (J5-07) and external antenna (BB3-06) EXT-3-900  Note: Only use the antenna recommended by Cervis, Inc. with the SmaRT base unit. Table 4. Compatible BU-xH8D P1 Cable Item Part # Wiring Harness...
  • Page 15: Smart Bu-Xh8D Base Unit Variations

    External (2) 0–10V OUT RS-232 BU-2H8D-INT-DIS-AO2-CAN 2.4GHz 100mW Internal (2) 0–10V OUT BU-2H8D-EXT-DIS-AO2-CAN 2.4GHz 100mW External (2) 0–10V OUT BU-2H8D-INT-DIS 2.4GHz 100mW Internal RS-232 BU-2H8D-EXT-DIS 2.4GHz 100mW External RS-232 BU-2H8D-INT-DIS-CAN 2.4GHz 100mW Internal BU-2H8D-EXT-DIS-CAN 2.4GHz 100mW External 2019 Cervis, Inc.
  • Page 16: Table 6. Smart Bu-9H8D Base Unit Variations

    SmaRT BU-xH8D Base Unit Family Table 6. SmaRT BU-9H8D Base Unit Variations Operating Antenna Analog Serial Model Display Frequency Power Channels Type Channels Port BU-9H8D-INT-AV2 900MHz 10mW Internal (2) 0–10V IN RS-232 BU-9H8D-EXT-AV2 900MHz 10mW External (2) 0–10V IN RS-232 BU-9H8D-INT-AV2-CAN 900MHz 10mW...
  • Page 17: Appendix A: Exposure To Radio Frequency Energy

     Note: Individual agency labels may differ, but SmaRT base unit models use the illustrated label position for all base unit agency labels. Figure 7. Agency Identification Label Locations 2019 Cervis, Inc.
  • Page 18: Appendix C: Typical Handheld To Base Unit Communication

    SmaRT BU-xH8D Base Unit Family Appendix C: Typical Handheld to Base Unit Communication Handheld remote and base unit communications are established at Cervis, Inc. before shipping when systems are ordered. However, it may be necessary to establish or re-establish communication between a remote and a base unit at some point. The Associate procedure is used to do this.
  • Page 19: Figure 8. Xx-2, 4, 6 Handheld Associate/Dissociate Buttons

    900MHz and 2.4MHz Manual Associate to Dissociate base unit from base unit Figure 8. XX-2, 4, 6 Handheld Associate/Dissociate Buttons 2019 Cervis, Inc.
  • Page 20 SmaRT BU-xH8D Base Unit Family To Dissociate In some circumstances, it may become necessary to break the communication link—or dissociate—a base unit and a PTO handheld remote. Caution Using the following steps breaks all previously established handheld remote links. It will be necessary to perform the Association Procedure (Appendix C1, above) using each handheld to re-establish communication links with a base unit.
  • Page 21: C2: Bu-Xh8D/Cb Remote Communication

    4. Observe the LEDs. All LEDs momentarily light solid. When the TX LED begins to blink, power up the base unit while continuing to hold SW13 and SW12. When TX, RX, ERR, and BAT light solid again, release SW13 and SW12. 2019 Cervis, Inc.
  • Page 22 SmaRT BU-xH8D Base Unit Family  Note: Be aware that all remote associations to the base unit are now broken. U088.4.4-SmaRT_BU-xH8D...
  • Page 23: C3: Bu-Xh8D/Mcb Remote Communication

    4. Observe the LEDs. When the TX LED begins to blink, power up the base unit while continuing to hold S1 and the Power button. When all four LEDs light solid, release S1 and Power Button. Association is successful when the TX and RX LEDs are rapidly flashing in unison. 2019 Cervis, Inc.
  • Page 24: Figure 10. Mcb Switch Actuation For Associate And Dissociate

    SmaRT BU-xH8D Base Unit Family ASSOCIATE Pull Pull Power ON DISSOCIATE Figure 10. MCB Switch Actuation for Associate and Dissociate To Dissociate (see Figure 10) The MCB remote must be OFF and the base unit must have power removed before beginning the Dissociation process.
  • Page 25: Appendix D: Declaration Of Conformity For Bu-2H8D

    900MHz and 2.4MHz Manual Appendix D: Declaration of Conformity for BU-2H8D 2019 Cervis, Inc.
  • Page 26 SmaRT BU-xH8D Base Unit Family U088.4.4-SmaRT_BU-xH8D...
  • Page 27 900MHz and 2.4MHz Manual www.cervisinc.com Visit our Web site at: 2019 Cervis, Inc. All rights reserved. Content is subject to change without notice. 2019 Cervis, Inc.

Table of Contents