Neumann.Berlin TLM 67 Operating Manual

Neumann.Berlin TLM 67 Operating Manual

Hide thumbs Also See for TLM 67:

Advertisement

Available languages

Available languages

Quick Links

TLM 67
Bedienungsanleitung
Operating Manual
2
7

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TLM 67 and is the answer not in the manual?

Questions and answers

Summary of Contents for Neumann.Berlin TLM 67

  • Page 1 TLM 67 Bedienungsanleitung Operating Manual...
  • Page 2 Schaltungsdesign mit charakteristischen • Betrieb an unsymmetrischen oder mittengeer- Eigenschaften der Originalröhre EF 86 geben dem deten Eingängen TLM 67 eine Klangabstimmung, die sich an das • Hinweise zur Pflege des Mikrofons U 67 anlehnt. Zum weltweiten Erfahrungsaustausch unter Neu-...
  • Page 3 Störschallunterdrückung Kabel mit dem Mikrofoneingang Ihres weiterver- arbeitenden Audiogerätes bzw. mit dem vorgese- Der Übertragungsbereich des TLM 67 reicht bis henen P48-Speisegerät. Hinweise zur Anschluss- unter 20 Hz. Entsprechend empfindlich ist das Mi- belegung finden Sie im Kapitel Technische Daten.
  • Page 4 Fehlercheckliste ▶ ▶ Fehler Mögliche Ursachen Abhilfe Keine Phantom-Speisespannung am Überprüfen Sie die entsprechenden Einstel- Funktion Mischpult oder am Speisegerät nicht lungen auf dem Kanalzug. eingeschaltet. Das Speisegerät ist nicht mit dem Überprüfen Sie Netzanschluss oder Batterie des Netzanschluss verbunden oder Speisegeräts.
  • Page 5 Technische Daten und Das Mikrofon besitzt einen symmetrischen, über- tragerlosen Ausgang. Der 3-polige XLR-Steck- Anschlussbelegungen verbinder weist folgende normgerechte Belegung Zulässige klimatische Verhältnisse: auf: Betriebstemperaturbereich ....0 °C … +70 °C Pin 1: 0 V/Masse Lagerungstemperaturbereich..–20 °C … +70 °C Pin 2: Modulation (+Phase) Feuchtebereich ..
  • Page 6 Ausgewähltes Zubehör* (Fotos im Anhang) Elastische Aufhängungen EA 87 ......ni ....Best.-Nr. 007297 EA 87 mt ....sw ....Best.-Nr. 007298 Mikrofonneigevorrichtung MNV 87 ....ni ....Best.-Nr. 006804 MNV 87 mt ....sw ....Best.-Nr. 006806 Stativgelenke, weitere mechanische Adapter DS 120 .....sw ....Best.-Nr. 007343 Tisch- und Fußbodenständer MF 3 ......sw ....
  • Page 7: Safety Instructions

    +49 (0) 30 / 41 77 24 - 0. EF 86 tube give the TLM 67 a sound quality simi- The following related files are available in PDF lar to that of the U 67.
  • Page 8: Shutdown And Storage

    Suppressing noise interference to be used for subsequent processing, or to the The frequency response of the TLM 67 extends designated P48 power supply equipment. Infor- below 20 Hz. The microphone is of course cor-...
  • Page 9: Troubleshooting

    Troubleshooting ▶ ▶ Problem Possible causes Solution Microphone not The phantom power supply voltage is Check the corresponding channel settings operating not switched on at the mixing console or at the power supply equipment The power supply equipment is not Check the connection to the power supply connected to the power supply line or line or check the battery of the power supply...
  • Page 10: Connector Assignments

    Technical data a The microphone has a balanced, transformerless output. The 3-pin XLR connector has the following connector assignments standard pin assignments: Permissible atmospheric conditions Pin 1: 0 V/Ground Operating temperature range ...0 °C to +70 °C Pin 2: Modulation (+phase) Storage temperature range ...–20 °C to +70 °C Pin 3: Modulation (–phase)
  • Page 11 Selected Accessories* (see photos in appendix) Elastic Suspensions EA 87 ......ni ....Cat. No. 007297 EA 87 mt ....blk ....Cat. No. 007298 Auditorium Hanger MNV 87 ....ni ....Cat. No. 006804 MNV 87 mt ....blk ....Cat. No. 006806 Stand Mounts, Misc. Mechanical Adapters DS 120 .....blk ....Cat.
  • Page 12 EA 87 (mt) MNV 87 DS 120 MF 3 MF 4 MF 5 WS 87 PS 15 PS 20 a BS 48 i BS 48 i-2 N 248...
  • Page 13 IC 3 mt IC 4 (mt) AC 25 13 13...
  • Page 14 10. Frequenz- und Polardiagramme 10. Frequency responses and polar patterns gemessen im freien Schallfeld nach IEC 60268-4, Toleranz ±2 dB measured in free-field conditions (IEC 60268-4), tolerance ±2 dB 14 14...
  • Page 15 15 15...
  • Page 16 Haftungsausschluss Die Georg Neumann GmbH übernimmt keinerlei Haftung für Folgen eines unsachgemäßen Gebrauchs des Produkts, d.h. die Folgen eines Gebrauchs, der von den in der Bedienungsanleitung genannten technischen Vorausset- zungen abweicht (z.B. Bedienungsfehler, mechanische Beschädigungen, falsche Spannung, Abweichung von empfohlenen Korrespondenzgeräten). Jegliche Haftung der Georg Neumann GmbH für Schäden und Folgeschä- den, die dem Benutzer aufgrund eines solchen abweichenden Gebrauchs entstehen sollten, wird ausgeschlossen.

Table of Contents