HTC S710D Manual page 60

Table of Contents

Advertisement

HTC CONFIDENTIAL
Light Sensor Calibration-1
Select "LSensor-Get Golden LS ADC" to get LUX
I.
value.
II.
Mark the position of the golden unit.
III.
Make sure the lighting condition is consistent.
IV.
Follow the instruction on the screen to save LUX
value. The value will be stored onto the micro SD
card.
Light Sensor Calibration-2
I.
Prepare the VIVO unit that had been repaired.
Light Sensor Calibration-3
I.
Use stored LUX value diagnostic card to load
diagnostic program into the repaired unit.
II.
Place the repair unit where the golden sample was
in.
III.
Make sure the lighting condition is consistent with
the golden unit.
IV.
Follow the instruction on the screen to choose
"LSensor-Set LS ADC" to write LUX value into the
repaired unit.
60
IS-5344-01-R3

Advertisement

Table of Contents
loading

Table of Contents