Page 3
Installation instructions Heat recovery appliance Renovent Excellent P300 STORE NEAR THE APPLIANCE This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Before starting installation of the heat recovery unit, check that it has been supplied complete and undamaged. The scope of delivery of the heat recovery unit Renovent Excellent P300 includes the following components: Heat recovery appliance type Renovent Excellent P300...
For the correct position of the connection ducts and dimensions see §3.2. indication on the multiple switch; The Renovent Excellent P300 comes ready to plug in with a which ensures that also at low outdoor temperatures 230 V mains plug and a connection for a low-voltage multiple the appliance's performance remains optimal and that, if switch on the outside of the appliance.
Discharges air from the dwelling to the atmosphere. 12 Supply fan Feeds fresh air into the dwelling. 13 Modular connector multiple switch X2 14 Connector eBus X1 Connection for eBus control 15 Mains cable 230 V Gland power cable 230 volt Renovent Excellent P300 Rev. D...
4.3 Frost protection To prevent freezing of the heat exchanger at extremely low That guarantees a proper ventilation balance, also at very low outdoor temperatures, the Renovent Excellent P300 features outdoor temperatures. intelligent frost control. Temperature sensors measure the tem-...
Installation must take place under: 5.2 Placing the appliance The Renovent Excellent P300 can directly be mounted to the wall using the suspension brackets supplied for that purpose. te discharge with air trap and pitch for condensate can be For a vibration-free result the appliance must be mounted to a made.
Page 15
Chapter 5 Installation 60 mm 1 = Renovent Excellent P300 left-handed 4/0 (place level) 6 = Preferred location extract ventilation air; use Brink 2 = Preferred ventilation air supply insulated ventilation roof sleeve. 3 = Ventilation air supply under the tiles...
The eBus protocol can for instance be used for coupling (cascade control) appliances (see §11.3). Because of polarity sensitivity, always connect contacts X1-1 to X1-1 and contacts X1-2 to X1-2 ; the appliance will not work when these contacts are interchanged! Renovent Excellent P300 Rev. D...
Four control keys can be used to call up and modify settings in the control unit program. When the mains power to the Renovent Excellent P300 Settings menu (SET); see § 6.3 is switched on, all display symbols will appear during 2 Readout menu (READ), see §...
The supply and extract fans are running under mode 3 of the multiple switch. This Renovent Excellent P300 is coupled with the aid of eBus. The supply and extract fans of the Renovent Excellent P300 are running under switched mode of the When using a 3-way switch, the position can not be used.
To modify other set values, repeat step 3 - 6. When you do not want to modify any more set values and return to operating situation, then press the ‘R’ key. Setting value Back to operating mode Step number setting value Terug naar bedrijfssituatie Renovent Excellent P300 Rev. D...
°C Current temperature outdoors sensor Bypass status (ON = bypass valve open, OFF = bypass valve closed) Status frost protection (ON = frost protection active, OFF = frost protection not active) Actual relative humidity (option) Renovent Excellent P300 Rev. D...
3. Activate the service menu. operating mode Fault code; refer to § 8.1 and§ 8.2 for explanation fault code the service menu during 5 seconds; This is only possible when there is no active fault! No. fault message Renovent Excellent P300 Rev. D...
2 sec. Nothing is shown on the display now. Directly after that the Renovent Excellent P300 will be run- ning in the mode is set on the multiple switch. If no multiple switch is connected, the appliance will always run in mode 1.
3; Mode 3 : Cooking/showering mode capacity 7.3 Other settings installer Various other settings of the Renovent Excellent P300 can also 7.4 Factory setting in one go. Renovent Excellent P300 was supplied from the factory; all message codes / fault codes will be erased from the service menu as well.
(if applicable) will be blinking. Contact the installer to remedy this fault. A locking fault cannot be remedied by taking Warning When working on the appliance, always take the voltage from the appliance by pulling the power plug. Renovent Excellent P300 Rev. D...
Page 26
(locking not set correctly. (see § 8.1). either. fault) Note! If mode 2 of a multiple switch does not work, the modular connector of the multiple switch has been connected the wrong way round. Renovent Excellent P300 Rev. D...
- Switch on the appliance by pressing the key ‘-’ during 5 seconds. > 5 sec. > 5 sec. taken out. “R The text “FILTER have been reset. Also when the message “FILTER 5 sec. FILTER operating mode. Renovent Excellent P300 Rev. D...
Rinse the exchanger with hot water (max. 45 ºC) and a regular detergent. Rinse the exchanger with hot water. Note! First disconnect the connectors on the rear of the display cover. Remove the move the front cover. Renovent Excellent P300 Rev. D...
Page 29
11 Clean the fans with a soft brush. Make sure the balancing weights do not shift! 12 Replace the separated part of the fan assembly 13 Place the complete fan assembly back into the appliance. Renovent Excellent P300 Rev. D...
O = E bus connector (polarity sensitive) or OpenTherm, E = Supply fan application depending on parameter setting 12 F = Extract fan Z = RH-sensor (option) G = Control panel H = Indoor temperature sensor Renovent Excellent P300 Rev. D...
Settings menu, also suitable as OpenTherm connector (see §11.3). Only suitable for low voltage. Note: Not suitable for 230V! Connector X2 Modular connector X2 for rpm control Modular connector type RJ-12. Only suitable for low voltage. Renovent Excellent P300 Rev. D...
Chapter 11 Electric connections accessories 11.2 Connection examples multiple switch A multiple switch can be connected to the modular connector X2 of the Renovent Excellent P300. This modular connector X2 is di- 230 V 50 Hz Wire colours C1 - C6 may vary dependent on the type of modular cable used.
Range Maximum safety with manual reset OFF = no preheater connected Preheater LED maximum safety; lights connected ON = preheater connected up when activated Cables to be connected by installer Flow direction through the heater Renovent Excellent P300 Rev. D...
When ordering parts, in addition to the article code number Example (see exploded view), please state the type of the heat recovery Appliance type : Renovent Excellent P300 4/0 R appliance, the serial number, the year of production and the name of the part: Serial number...
The product described above complies with the following directives: 2014/35/EU (low voltage directive) 2014/30/EU (EMC directive) RoHS 2011/65/EU (substances directive) 2009/125/EG (1253/1254 EU (EU ErP-directive)) The product bears the CE label: Staphorst, 24-02-11 W. Hijmissen, managing director Renovent Excellent P300 Rev. D...
Internet address for Assembly instructions: http://www.brinkclimatesystems.nl/installateurs/kenniscentrum/Documentatie.aspx Bypass: Yes; 100% Bypass * Measurements executed by TNO according to the EN 13141-7 standard (TNO-report TNO 2013 M10230, Februari 2013) SEC Class („Average climate“) SEC in kWh/m²/a SEC < -42 Renovent Excellent P300 Rev. D...
Page 42
BRINK CLIMATE SYSTEMS B.V. P.O. Box 11 NL-7950 AA Staphorst The Netherlands The Netherlands...
Need help?
Do you have a question about the Renovent Excellent P300 and is the answer not in the manual?
Questions and answers