Download Print this page

Midea Ultimate Comfort Series User Manual page 5

Hide thumbs Also See for Ultimate Comfort Series:

Advertisement

For a detailed explanation of each function,
refer to the Remote Control Manual.
Other Features
Auto-Restart
If the unit loses power, it will automatically
restart with the prior settings once power has
been restored.
Anti-mildew (some units)
When turning o the unit from COOL, AUTO
(COOL), or DRY modes, the air conditioner will
continue operate at very low power to dry up
condensed water and prevent mildew growth.
Silky Cool
--The optimized air outlet design enlarge the
air ow angle , so that you can enjoy an
evener comfortable cooling than before.
--The enlarged de ector blow the cooling
air ow upward avoiding direct air ow
blowing on the body .
--The Innovated Atomizer Wing de ector
with thousands of mini holes evacuates
centralized air ow into thousands of
small gentle air ow. The sensory is so
gentle and soft that it's as if you are
indulging in silky coolness.
Energy Saving
(applicable for Inverter type only)
Press the Gear button on the remote controller
to activate Energy Saving function. The power
consumption will be reduced according to the
Gear mode you selected. please refer to the
remote controller illustration for details.
NOTE ON ILLUSTRATIONS
Illustrations in this manual are for explanatory purposes. The actual shape of your indoor unit may be
slightly di erent. The actual shape shall prevail.
Wireless Control
(some units)
Wireless control allows you to control your air
conditioner using your mobile phone and a
Wireless connection.
For the USB device access, replacement,
maintenance operations must be carried
out by professional sta .
Louver Angle Memory(some units)
When turning on your unit, the louver will
automatically resume its former angle.
Refrigerant Leakage Detection
(some
units)
The indoor unit will automatically display "EC"
when it detects refrigerant leakage.
Air Fresh function
(some units)
Innovated Air Magic technology,
e ectively eliminates bacteria, virus,
microbes, and other harmful substances
and refresh the air.
For a detailed explanation of your unit' s
advanced functionality (such as TURBO mode
and its self-cleaning functions), refer to the
Remote Control Manual.
Page 8
Setting Angle of Air Flow
Setting vertical angle of air ow
While the unit is on, use the SWING(vertical air ow)
button to set the direction of air ow.
1. Press the SWING(vertical air ow) button
on the remote control once to activate the louver.
Each time you press the button, it will adjust the
louver by 6°. Press the button until the direction
you prefer is reached.
2. To make the houver swing up and down
continuously, press and hold the SWING
(vertical air ow) button for 3 seconds.
Press it again to stop the automatic function.
(see Fig.A)
Setting horizontal angle of air ow
While the unit is on, use the SWING(horizontal
air ow) button to set the direction of air ow.
1. Press the SWING(horizontal air ow) button
on the remote control once to activate the louver.
Each time you press the button, it will adjust the
louver by 6°. Press the button until the direction
you prefer is reached.
2. To make the houver swing left and right
continuously, press and hold the SWING
(horizontal air ow) button for 3 seconds.
Press it again to stop the automatic function.
(see Fig.B)
NOTE ON LOUVERS
Do not move louver by hand. This will cause the
louver to become out of sync. If this occurs, turn
o the unit and unplug it for a few seconds,
then restart the unit. This will reset the louver.
Silky Cool Operation
Press the Silky button on the remote control to
activate the Silky cool operation. The air conditioner
will adjust the louver angle automatically on the
basis of room temperature and humidity variable.
There are four di erent operation state, See Fig. C1,
Fig. C2, Fig. C3, Fig. C4 .
Page 9
Fig. A
Fig. B
CAUTION
Do not put your ngers in or near the
blower and suction side of the unit. The
high-speed fan inside the unit may
cause injury.
Fig. C1
Fig. C2
Fig. C3
Fig. C4