– After the wet vacuuming: Clean the flat
folded filter with the filter cleaning.
Clean the electrodes with a brush.
Clean the container with a damp rag
and dry it.
Clip connection
Illustration
The suction hose is equipped with a clip
system. All accessories with a nominal
width of 35 mm can be connected.
Operation
Rotating knob
Appliance OFF
Appliance ON
Automatic filter cleaning: OFF
Appliance ON
Automatic filter cleaning: maxi-
mum interval
Appliance ON
Automatic filter cleaning: mini-
mum interval
Turning on the Appliance
Plug in the mains plug.
Set the rotary switch to the desired pro-
gram.
Adjust the suction output
Set the suction output (min - max) at the
rotary switch.
Working with electrical power tools
DANGER
Risk of injury and damage! The socket out-
let is only for the connection of power tools
to the vacuum cleaner. Any other use of the
socket outlet is not permitted.
Connect the mains plug of the electric
power tool to the vacuum cleaner.
The vacuum cleaner is in standby
mode.
Switch on the appliance at the rotating
knob.
22
Note: The vacuum cleaner is turned on and
off automatically with the electric power
tool.
Note: The vacuum cleaner starts automat-
ically within 0.5 seconds and continues to
run for 15 seconds after the power tool has
being switched off.
Note: Please refer to "Technical specifica-
tions" for the power connection specifica-
tions of the power tools.
Illustration
Remove the elbow from the suction
hose.
Attach the tool adapter to the suction
hose.
Illustration
Connect the tool adapter to the electric
power tool.
Note: The different suction hose sections
are required to allow an adjustment to the
connection sections of the processing
tools.
Set the minimum volume flow for the
suction hose cross section at the rotary
switch.
The scale displays the suction hose cross
section.
Note: To use the appliance as dedusting
device for the mobile operation (processing
tool connected to the vacuum cleaner) the
built-in monitoring must be adjusted to the
connected processing tool (dust-generat-
ing device). This means that the user must
be warned if the minimum volume flow of
20 m/s that is required for the suction is fall-
en short of.
Note: Please refer to the type plate for the
specification of the minimum volume flow in
dependence on the negative pressure.
Automatic filter cleaning
The device is equipped with a special filter
dedusting function, which is particularly ef-
fective against fine dust. The flat fold filters
are automatically cleaned every 15 sec-
onds (AUTO MAX) or every 60 seconds
(AUTO MIN) by a blast of air (pulsing
noise).
– 5
EN