Bosch mm-Si plus EU1510 Series Planning And Installation Instructions
Bosch mm-Si plus EU1510 Series Planning And Installation Instructions

Bosch mm-Si plus EU1510 Series Planning And Installation Instructions

Advertisement

For Specialists
Version : ENG/2011/12
Solar Energy
Planning and Installation Instructions
μm-Si plus EU1510
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the mm-Si plus EU1510 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Bosch mm-Si plus EU1510 Series

  • Page 1 For Specialists Version : ENG/2011/12 Solar Energy Planning and Installation Instructions μm-Si plus EU1510...
  • Page 2: Table Of Contents

    Solar Energy List of Contents SAFETY INSTRUCTIONS AND EXPLANATION OF SYMBOLS Safety instructions Explanation of symbols General safety instructions GENERAL PRODUCT PROPERTIES Specifications for the product series Specifications for the junction box system Nameplate Intended use Normal conditions of use / environmental conditions EC declaration of conformity Certification INSTRUCTIONS ON THE SYSTEM LAYOUT...
  • Page 3: Safety Instructions And Explanation Of Symbols

    Solar Energy General safety instructions 1 Safety instructions and For your own safety and that of your employees or explanation of symbols third parties and for the protection of the system you are installing, please follow the safety instructions in this section as well as those in Section 5.
  • Page 4: General Product Properties

    -40 to +90 °C Note: Electrical parameters are typical mean values from historical production data. Bosch Solar Energy AG does not assume any guarantee for the accuracy of this data for future production batches. All data and figures are subject to a tolerance of 10 %, unless...
  • Page 5: Nameplate

    The serial num- Note: ber is also featured as a Code 39 (3of9) barcode. Bosch Solar Energy AG's warranty and guarantee be- comes null and void if the module and module com- ponents (couplers, cabling, junction box, label and...
  • Page 6: Ec Declaration Of Conformity

    30° ± 15° with the solar module's active surface facing the You can find these product certificates at www.bosch- Equator. You can find more detailed informa- solarenergy.de.
  • Page 7: Guidelines On The Electrical System Layout

    If μm-Si plus EU1510 modules are not installed using  The location of a PV system must be care- the Bosch Solar Rack Slide mounting system, a func- fully selected. If a system is placed near tional grounding system must be fitted to the module's...
  • Page 8: Guidelines For Attaching Solar Modules Up To 2,400 Pa

    Solar Energy In view of these considerations, Bosch a-Si plus solar modules are to be mounted by trained specialists in  You should fasten the solar module connec- accordance with recognized technical standards while tion cables without applying tensile stress on taking into account applicable industrial standards the junction box.
  • Page 9 Solar Energy   Solar modules must be firmly mounted in The clamps may be placed over the glass to permanently elastic bedding. The solar mod- a maximum depth of 15 mm; this depth must ule and its glass must not come into direct be at least 8 mm to allow for installation and contact with metal components in the sub- position tolerances.
  • Page 10: Transport And Storage Before Installation

    Solar Energy Transport and storage before in- stallation One packaging unit contains 20 solar modules and consists of a two-section cardboard box standing on a Euro-pallet. Instructions on storing modules in transport packag- ing:  No more than two packaging units may be stacked on top of one another, i.e.
  • Page 11: Standards And Regulations

    Solar Energy 5 Installation 4 Standards and regulations Safety instructions The following standards and regulations must be μm-Si plus EU1510 Series solar modules are glass taken into account during planning, installation and products and convert light into electrical energy even maintenance.
  • Page 12: Storage And Transport On The Construction Site

    Solar Energy Module installation Storage and transport on the con- struction site  Two people are needed to lift the modules out of their packaging and carry them to the A transport packaging unit contains 20 μm-Si plus installation location. EU1510 solar modules, in which solar modules are graded according to their performance class.
  • Page 13: Electrical Connection

    Only original replacement parts should be used during Environmental protection is a key principle of the maintenance. Bosch Group's company policy. Product quality, prof- itability, and environmental protection are equally im- Danger! portant goals for us. Environmental protection laws Shut the system down before carrying out any work! and regulations are strictly complied with.
  • Page 14: Inspection

    Solar Energy Note: Solar modules positioned at a low angle accumulate Cleaning dirt more easily. You can find instructions on mainte- nance-friendly installation in Section 3.  You should use soft cloths and plenty of wa- Note: ter for cleaning. The system should not be maintained in direct sunlight or under extremely high insolation conditions ...
  • Page 15: Contact Addresses, Contact Persons

    Planning and Installation Instructions for the μm-Si plus EU1510 Series © Bosch Solar Energy AG, December 2011 Version: ENG/2011/12 We reserve the right to make any changes as a result of technical advances and may do so without prior no-...

Table of Contents