Defiant NC Clearance Chart for 8" Connections ONLY
Top exit with no
connector heat shields.
Flue collar shield installed
Top exit with heat shields
on connector. Flue collar
shield installed
Top exit double-wall
chimney connector*. Flue
collar shield installed
Rear exit
Single-wall connector
Single-wall connector
with shields
Double-wall chimney
connector
Single-wall connector
(Horizontal)
A minimum ceiling height of 8 feet (2.4 m) measured from the base of the stove is required for all installations.
* Using a listed double wall oval to round connector.
1. Most installations require a ceiling heat shield 24" (610 mm) in diameter and suspended 1" (25 mm) from the ceiling that must
surround the pipe when the chimney penetrates the ceiling. Refer to Notes 3 and 4 below for the only exceptions to this. The
ceiling heat shield is always required if clearances are reduced using wall protection.
2. With protected wall surfaces, the rear clearance must be increased by 3" (76 mm) if the flue collar heat shield is not used. The
flue collar shield is required when using connector pipe shields and always with unprotected surfaces.
3. In installations where the ceiling height is 9 feet (2.7 m) or more and if wall protection is not used, the ceiling heat shield is not
necessary.
4. Connector pipe heat shields must extend the entire length of the connector pipe up to 9 feet (2.7 m). In installations where the
ceiling height is 10 feet (3 m) or more and if wall protection is not used, the ceiling heat shield is not necessary.
30002850
Unprotected Surfaces
Stove Installed
Parallel to Wall
Side
Rear
(A) 24"
(B) 35"
3
3
(610 mm)
(889 mm)
(G) 26"
(H) 17"
4
4
(660 mm)
(430 mm)
(M) 25"
(N) 22"
(635 mm)
(559 mm)
(S) 21"
(T) 21"
(533 mm)
(533 mm)
Chimney Connector Clearance
Unprotected Vertical Surfaces
29¹⁄₂" (749 mm)
11¹⁄₂" (292 mm)
16¹⁄₂" (419 mm)
Unprotected Ceiling Surfaces
30" (762 mm)
Clearance to Combustibles in Front of Stove
All Installations
Defiant 1610 Non-Catalytic Woodburning Stove
Stove Clearance
1
Protected Surfaces
Stove
Stove Installed
in
Parallel to Wall
Corner
Corners
Side
(C) 25"
(D) 11"
3
(635 mm)
(279 mm)
(I) 25"
(J) 11"
4
(635 mm)
(279 mm)
(O) 14"
(P) 8"
(356 mm)
(203 mm)
N/A
(U) 8"
(203 mm)
Protected Vertical Surfaces
Protected Ceiling Surfaces
48" (1219 mm)
Stove
in
Corner
Rear
Corners
2
(E) 15"
(F) 9"
(381 mm)
(229 mm)
(K) 15"
(L) 9"
(381 mm)
(229 mm)
(Q) 11"
(R) 6"
(279 mm)
(152 mm)
(V) 21"
N/A
(533 mm)
9¹⁄₂" (241 mm)
9¹⁄₂" (241 mm)
5¹⁄₂" (140 mm)
19" (483 mm)
15