ODGSR Series Outdoor Gas Fireplace
Framing and Finishing
Check appliance to make sure it is levelled
and properly positioned.
The appliance should only be mounted on the following
surfaces:
A flat combustible (burnable) surface.
A raised wooden platform.
A concrete block or other solid object placed
beneath each of the four corners of the appliance.
To mount the appliance:
1. Choose unit location.
2. Four (4) nailing flanges are supplied with the fire-
place (found on the fireplace hearth). To level the
box and secure it firmly in place, remove the nailing
flanges from the hearth and install at the sides of the
fireplace as shown in Figure 4.
Fig. 4 Adjustable drywall strip (nailing flange).
Finishing
CAUTION: All joints between the finished
wall and the appliance surround (top and
sides) may be sealed only with non-com-
bustible material. Only noncombustible
material can be applied as facing to the ap-
pliance surround (the black painted face).
Finish the wall with the material of your choice. Refer to
Figures 3a and 3b for specific clearances when install-
ing a combustible mantel or other combustible projec-
tion.
6
Nail Top
Standoffs
Nail Side-
Nailing
Flanges
FP549
FP549
9/29/97
BR/BC
Gas Specification
Model
Fuel Gas Control
ODGSR36ARN
Nat.
ODGSR36ARP
Prop.
ODGSR42ARN
Nat.
ODGSR42ARP
Prop.
Gas Inlet & Manifold Pressures
Minimum Inlet Pressure
Maximum Inlet Pressure
Manifold Pressure
ODGSR36A / ODGSR42A
Certified to
CSA 4-96
Units: G01AU6, G01BU6, G01AU2, G01BU2

High Elevations

Input ratings are shown in BTU per hour and are
certified without deration from elevations up to
4,500 feet (1,370 m) above sea level.
Nuisance outages may occur at altitudes above
4,500 feet (1,370 m) if dirt, dust, lint and/or cob-
webs are allowed to accumulate on burner and/or
ODS pilot. Monthly inspection and cleaning is rec-
ommended for altitudes above 4,500 feet (1,370 m)
For elevations above 4,500 feet (1,370 m), instal-
lations must be in accordance with the current
ANSI Z223.1/NFPA 54 and/or local codes having
jurisdiction.

Valve Access

Valve access can be accomplished in one of two ways:
1. Remove the front panel just below the front of the
hearth pan. This is accomplished by lifting on the
panel. To replace the valve access panel line up the
two pins with the holes in the surround bottom and
push the panel over the front of the hearth pan. (Fig.
5)
2. Lift the brick with the Majestic logo on it. (Fig. 6)
Max.
Min.
Input
Input
Millivolt Hi/Lo
60,000 42,600
Millivolt Hi/Lo
60,000 44,000
Millivolt Hi/Lo
60,000 42,600
Millivolt Hi/Lo
60,000 44,000
Natural
LP
5.5" w.c.
11.0" w.c.
14.0" w.c.
14.0" w.c.
3.5"w.c.
10.0" w.c.
20007114