Majestic ODGSR36A Homeowner's Installation And Operating Manual

Outdoor gas fireplace

Advertisement

Outdoor Gas Fireplace
Models: ODGSR36A, ODGSR42A
INSTALLER/CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE.
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
WARNING: Improper installation,
adjustment, alteration, service or
maintenance can cause injury or
property damage. Read the installation,
operating and maintenance instructions
thoroughly before installing or servicing
this equipment.
WARNING:
For Outdoor Use ONLY.
Homeowner's Installation and
Operating Manual
7114
ODGSR
cover
11/03
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
C E RT I F I E D
20007114 5/09 Rev. 14

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ODGSR36A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Majestic ODGSR36A

  • Page 1 Outdoor Gas Fireplace Models: ODGSR36A, ODGSR42A INSTALLER/CONSUMER SAFETY INFORMATION PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 2: Table Of Contents

    Troubleshooting ......................... 14 Maintenance ..........................15 Replacement Parts ........................16 Accessories ..........................18 Warranty ............................19 IMPORTANT: Proposition 65 Warning: Fuels used in gas, wood- burning or oil fired appliances, and the products of PLEASE READ THE FOLLOWING CAREFULLY combustion of such fuels, contain chemicals known to Remove any plastic from trim parts before turning the the State of California to cause cancer, birth defects fireplace “ON”. and other reproductive harm. California Health & Safety Code Sec. 25249.6 It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine. It is not unusual for your Majestic Fireplaces gas fire- place to give off some odor the first time it is burned. This is due to the curing of the paint and any unde- tected oil used in the manufacturing process. It is recommended that you burn your fireplace for at least ten (10) continuous hours the first time you use it. 20007114...
  • Page 3: Installation & Operating Instructions

    ODGSR Series Outdoor Gas Fireplace General Information This gas appliance should be installed by a qualified Enclosures for LP-Gas Supply Systems installer in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Enclosures for LP-gas supply cylinders shall be ventilated by Appliances and Equipment. openings at the level of the cylinder valve and at floor level. The effectiveness of the opening(s) for purposes of ventilation shall FOR U.S.A Installations follow local codes and/or the cur- be determined with the LP-gas supply cylinder(s) in place. This rent National Fuel Gas Code. ANSI Z223.1/NFPA 54. shall be accomplished by one of the following: a. One side of the enclosure shall be completely open; or In the Commonwealth of Massachusetts, all gas fittings b. For an enclosure having four sides, a top and a bottom: and installation of this heater shall only be done by a 1. At least two ventilation openings at cylinder valve level licensed gas fitter or licensed plumber. shall be provided in the side wall, equally sized, spaced at FOR SAFE INSTALLATION AND OPERATION PLEASE 180 degrees (3.14rad), and unobstructed. Each opening NOTE THE FOLLOWING: shall have a total free area of not less than 1/2 square...
  • Page 4: Fireplace Dimensions

    3 " (210mm) (95mm) 14 " 40" 3 " 3 " " (362mm) (1016mm) (95mm) (98mm) (165mm) Gas Line Access Fig. 1 ODGSR36A specification and framing dimensions. Fireplace Dimensions 7114 " ODUVSR36A (667mm) Specs Rough 11/03 Opening Depth 50" (1270mm) " (13mm) " (572mm) 22"...
  • Page 5: Moisture Resistance

    ODGSR Series Outdoor Gas Fireplace Moisture Resistance Mantels This outdoor fireplace will shed moderate amounts of WARNING: A 4" hood must be used if a water, but is not waterproof. Water and condensing wa- mantel is to be installed. ter vapor may enter the chase under certain conditions. The height that a combustible mantel is fitted above the The fireplace will not perform as an exterior wall. Mois- fireplace is dependent on the depth of the mantel. This ture penetration must be considered for construction also applies to the distance between the mantel leg (if that places the fireplace in structure walls or on mois- fitted) and the fireplace. ture sensitive surfaces. For the correct mounting height and widths refer to When installed on exterior walls: MHSC recommends Figures 3a and 3b the fireplace chase be constructed outside the struc- ture's weather envelope. Where the platform meets Noncombustible mantels and legs may be installed at the wall, use a flashing detail similar to that required any height and width around the appliance. for attached decks. Chase platforms, including hearths When using paint or lacquer to finish the should slope away from the structure at 1/4 in per foot. mantel, such paint or lacquer must be heat The fireplace can be shimmed level.
  • Page 6: Moisture Resistance

    ODGSR Series Outdoor Gas Fireplace Hearths should slope away from the front of the fire- place and chase at 1/8 in to 1/4 in per foot. Metal safety strips must be on top of any combustible hearth materi- als used for moisture management. Framing and Finishing Black Check appliance to make sure it is levelled Mantel Surround and properly positioned. Face CFM164 The appliance should only be mounted on the following surfaces: Side of CFM164a Combustion Chamber Mantel Leg Chart • A flat combustible (burnable) surface. 06/22/01 sta •...
  • Page 7: Gas Specifications

    Fig. 5 Valve access. Maximum Inlet Pressure 14.0” w.c. 14.0” w.c. Manifold Pressure 3.5”w.c. 10.0” w.c. FP1414 ODUVSR valve access ODGSR36A / ODGSR42A 11/24/03 djt Certified to CSA 4-96 Majestic Logo Brick High Elevations FP1415 Input ratings are shown in BTU per hour and are Fig. 6 Lift brick with logo on it to access valve. certified without deration from elevations up to 4,500 feet (1,370 m) above sea level.
  • Page 8: Exterior Chase Installation

    ODGSR Series Outdoor Gas Fireplace Gas Line Installation *Do not install header until unit is in place. This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure equal to or less than 1/2 psig (3.45 kPa). Standoff Surround The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during Gas any pressure testing of that system at test pressures in Nailing Line Ac- Flange cess excess of 1/2 psig (3.45 kPa). If gas piping from the source to the appliance location has not been accomplished, install the required pipe. Consult local plumbing code to assure proper pipe size. Screen The gas pipeline can be brought in through the right Grate side of the appliance. A knockout is provided to allow Firebox for the gas pipe installation and testing of any gas con- Valve Access Panel nection. FP1416 NOTE: The gas line connection can be made with 3/8" Fig.
  • Page 9: Remote Wall Switch

    ODGSR Series Outdoor Gas Fireplace Remote Wall Switch NOTE: Use an approved outdoor switch. Pilot 1. Thread wire through the low voltage wire access hole located on either side of unit. Do not cut wire or insu- lation on metal edges. Ensure that wire is protected. Run the other end to a conveniently located wall receptacle box. 2. Attach wire to switch and install switch into receptacle Thermodisk box. Attach cover plate to switch. 3. Connect wiring to gas valve. Refer to Figure 11. CAUTION: Do not wire millivolt remote wall switch for gas appliance to a 120v power supply. For lighting instructions, refer to Page 12. Valve NOTE: If glass doors are installed, the unit must be operated with the doors fully open.
  • Page 10: Operating Instructions

    ODGSR Series Outdoor Gas Fireplace Operating Instructions Log Installation Right Cross 1. Remove logs from the packaging. As with all plastic, these bags Left Cross are not toys and should always be kept away from children and infants. 2. Place left rear log on rear log support. Right Rear Ensure that log is firmly positioned and there is no side-to-side movement. (Figs. 13 & 14) 3. Carefully place Ember Log between grate and burner. (Figs. 13 & 14) Left Rear 4. Place the front of right rear log on the burner and the back of the log on the Ember rear log support.
  • Page 11: Flame Adjustment

    FP581 flame height Fig. 16 Proper pilot flame height. Fig. 15 Flame adjustment knob for SIT820 valve. FP581 Flame Characteristics FP390 NVB-PILOTS FLAME ADJUSTMENT KNOB It is important to periodically perform a visual check of 12/4/97 11/21/96 the pilot and the burner flames. Compare them to the il- lustrations below (Figs. 16, 17, 18). If any of the flames appear abnormal call a service person. Red Glow LG319 Fig. 17 ODGSR36A flame appearance. LG319 ODUVSR36 log flames 11/24/03 djt LG320 Fig. 18 ODGSR42A flame appearance. 20007114...
  • Page 12: Optional Weather Enclosures

    ODGSR Series Outdoor Gas Fireplace Optional Weather Enclosure Optional Stainless Steel Hood An optional weather enclosure is available to protect An optional stainless steel hood is available for both the the burner when not in use. ODGSR36A and ODGSR42A. CAUTION: Do not use the weather enclosure NOTE: The stainless steel hood may NOT if the unit has glass doors installed. be used when the optional glass doors are installed. Installation Instructions Installation Instructions: 1. Turn the unit OFF and allow to cool.
  • Page 13: Lighting & Operating Instructions

    ODGSR Series Outdoor Gas Fireplace Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manu- • If you cannot reach your gas supplier, call the ally. When lighting the pilot follow these Fire Department...
  • Page 14: Troubleshooting

    ODGSR Series Outdoor Gas Fireplace Troubleshooting Nova SIT 820 Standing Pilot START CHECK Supply Line Hooked up Gas Supply On Shutoff Valve Open Lockout has engaged. Wait 60 seconds and try again. Piezo not tight enough for good ground. Pilot Lights with For spark at electrode while Piezo Ignitor depressing Piezo (Red Button)
  • Page 15: Maintenance

    ODGSR Series Outdoor Gas Fireplace Maintenance Burner and Burner Compartment Cleaning the Standing Pilot It is important to keep the burner and the burner Control System compartment clean. At least once per year the logs The burner and control system consists of: should be removed and the burner compartment vacuumed and wiped out. Remove and replace the logs • main burner as per the instructions in this manual. • gas orifice Always handle the logs with care as they are fragile • pilot burner and may also be hot if the fireplace has been in •...
  • Page 16 ODGSR Series Outdoor Gas Fireplace 1. ODGSR36A Logs 1. ODGSR42A Logs 4a/b 12a/b 19a/b 7114 18a/b MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. ODGSR36A, ODGSR42A Ref. Description ODGSR36A ODGSR42A 1. Logs - Complete Set 20007180 20007200 1a. Log - Left Rear 20007175 20007193 1b. Log - Right Rear 20007176 20007194 7114 1c. Log - Right Cross 20007178 20007197 oduvsr36/42A 1d. Log - Left Cross...
  • Page 17: Replacement Parts

    ODGSR Series Outdoor Gas Fireplace ODGSR36A, ODGSR42A (continued) Ref. Description ODGSR36A ODGSR42A 14. Pilot Tubing 10001296 10001296 15. Cable Ignitor 24" 7522432 7522432 16. Thermocouple 24" 7531137 7531137 17. Grate 20006819 20006819 18a. Pilot Orifice - Natural 10002268 10002268 18b. Pilot Orifice - LP 10002269 10002269 19a. Valve NOVA - Natural 7529141 7529141 19b. Valve NOVA - LP...
  • Page 18: Accessories

    ODGSR Series Outdoor Gas Fireplace Accessories The following accessories are available from your local Majestic Fireplaces distributor. Each accessory comes with a separate installation instruction for mounting to the particular firebox. Be sure to read each instruction thoroughly before installing. Accessory Description Model Number 4" Stainless Steel For heater up to 40,000 BTU's and mantels UV36SH4 Hood 8" high by 12" wide UV42SH4 Glass Doors Designed to enhance the look of the fireplace 36GDKSSSR 42GDKSSSR Weather Enclosure Designed to protect the burner when unit is not in use ODG36WE ODG42WE Drain Pan Designed to be installed under unit to shed water 20014194 (36" models) by means of containing and piping way from structure 20014195 (42" models) CAUTION: This firebox is a highly engineered system, and, as such, must be operated only with MHSC ap- proved components.
  • Page 19: Warranty

    ODGSR Series Outdoor Gas Fireplace LIMITED WARRANTY Factory-Build Fireplace and Components (Except Blowers) What is Covered and For How Long Five-Year Coverage: For five years from the date this fireplace and components are first purchased for use, MHSC will, at its option, repair or replace any defective part of this fireplace or components, or refund to you a sum not to exceed the factory retail price in effect at the time of purchase. Ten-Year Coverage: From the sixth through the tenth year following the date this fireplace or accessory is first purchased for use, MHSC will make available to you, at our factory, a free replacement for any defective part in this fireplace or accessory. Twenty-Five-Year Availability of Replacement Parts: From the eleventh through the twenty-fifth year following the date this fireplace or accessory is first purchased for use, MHSC will make available at our factory replacement parts for this fireplace or accessory, which you may purchase for the list price current at the time your purchase order is received. What is Not Covered • This limited warranty does not cover: • Transportation or shipping cost.
  • Page 20 MHSC 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.com...

This manual is also suitable for:

Odgsr42a

Table of Contents