Clearance To Combustibles; Mantels; Mantel Chart; Hearth - Majestic ODGSR36A Homeowner's Installation And Operating Manual

Vermont castings outdoor gas fireplace homeowner's installation and operating manual odgsr36a, odgsr42a
Table of Contents

Advertisement

Screened Porch Installation
The ODGSR may be installed safely and is design
certified by CSA to be installed in a screened porch with
these guidelines:
Minimum porch area ...............................96 sq. feet (9sq m)
Minimum celing height ................................. 92" (2,337 mm)
Minimum of two (2) walls must be screened
Minimum top of screen height, side walls ....6'6" (1,981 mm)
Minimum screen area .............................64 sq. feet (6sq m)

Clearance to Combustibles

Appliances
Top ..........................................................0" (0 mm)
Bottom .....................................................0" (0 mm)
Side .........................................................0" (0 mm)
Back ........................................................0" (0 mm)
Perpendicular Sidewall ...........................0" (0 mm)
Top of unit to ceiling ..........................36" (914 mm)
Front of unit to combustibles .............36" (914 mm)

Mantels\

WARNING: A 4" hood must be used if a
mantel is to be installed.
The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This
also applies to the distance between the mantel leg (if
fitted) and the fireplace.
For the correct mounting height and widths refer to
Figures 3a and 3b
Noncombustible mantels and legs may be installed at
any height and width around the appliance.
Side View
A
B
Ref.
Mantel
CFM146
Shelf Depth
DV Mantel Chart
7/5/01 sta
Y
8" (203 mm)
Z
1¹⁄₂" (38 mm)
Fig. 3a Mantel clearances.
20007114
Y
Z
Fireplace
Top of Combustion
Chamber
CFM146
Ref.
Mantel From Top
of Comb. Chamber
A
28"
(711 mm)
B
26"
(660 mm)
ODGSR Series Outdoor Gas Fireplace
Black Sur-
Mantel
round Face
Leg
CFM164
CFM164a
Side of
Mantel Leg Chart
Combustion Chamber
06/22/01 sta
Ref.
Mantel
Leg Depth
CFM170
F
14" (356 mm)
DV Builder Front
G
12" (305 mm)
View
H
10" (254 mm)
I
8"
(203 mm)
J
1¹⁄₂" (38 mm)
Fig. 3b Combustible mantel leg minimum installation.
When using paint or lacquer to finish the
mantel, such paint or lacquer must be heat
resistant to prevent discoloration.

Hearth

A hearth is not mandatory but is recommended for
aesthetic purposes. We recommend a noncombustible
hearth.
J
I
H
G
F
K
L
M
N
O
CFM170
Ref.
Mantel Leg From
of Comb. Opening
K
14"
(356 mm)
L
12"
(305 mm)
M
10"
(254 mm)
N
8"
(203 mm)
O
1¹⁄₂"
(38 mm)
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Odgsr42aOdgsr42a

Table of Contents