4. Attach one end of the Flexible Gas Connector to
the brass Burner Inlet Fitting which has been factory
installed into the burner.
5. Attach the other end of the Gas Connector to the
flared side of the Gas Supply Fitting.
Remember to use pipe thread sealant or teflon tape
only on the straight pipe threads. Do not use on
any flared ends.
NOTE: Your gas log set is assembled at the factory to be installed in a fireplace plumbed with the gas on
the right side (facing). If your fireplace is plumbed with the gas on the left side remove fittings on right and
left side of straight burner tube and switch sides, at the same time put front burner tube on right side with
the elbow fitting. (Refer to Figs. 3,4)
You may also run a flexible connector (or as per local codes) along the back wall of the fireplace to bring
your gas line to the right hand side. You can then place the set in front of the flexible connector. (Fig. 4)
Fig. 3 LP gas connection.
Fig. 4 Alternate left side gas connection.
20007967
Gas Plumbed on Left Hand Side of Fireplace
Regulator
Supplied w/LP Unit
3/8" Brass Elbow
NPT to Flare
FP1484
OD24SHK
LP hook up
5/04 djt
FP1485
FP1485
alternate left side
gas connection
5/10/04 djt
Fig. 2 Natural gas connection.
CFM149
R-CFL Gas Supply Connection
2/14/01 sta
Rigid Pipe. Flexible Hose or Copper Tubing
Approved for Outdoor Use
Gas Inlet 3/8"
Pipe Coupling
Parts Not
Supplied
Flex Hose
CFM149
To Gas Supply
FP1484
FP1486
FP1486
5