Page 2
13. FINISHING 13.a Cover mainhousing 13.b Cover poles 13.c Cover plate bottom arm 13.d Fabric fixation profile 13.e Fitting sealing rubbers 13.f Triangular screen 13.g Mounting sideplates 13.h Endcap hinge 13.i Roof covers 14. FITTING MODULES AGAINST EACH OTHER OL-B500-00...
Page 3
Groundanchor Pole support (standard) 7-7/8” x 7-7/8” Floorplate 20 x 20cm SECTIONS Arm profile Mainhousing Cover vertical couple pole Door pole Vertical pole Support for groundanchor 7-7/8” x 7-7/8” or floorplate 20cm x 20cm Pole support couple pole (standard) OL-B500-01...
Page 4
› Check the fixation by measuring diagonally - the deifference may be no more than 5mm. No screens on L1 or L2 Pole Support Ground Anchor Floorplate 7-7/8” x7-7/8” W-3/8” W-3-1/2” W-3-1/2” Screens on L1 and/or L2 Pole Support Ground Anchor Floorplate 20x20 7/8” 7/8” 7/8” W-3/8” W-3-1/2” W-3-1/2” OL-B500-02...
Page 5
Vertical pole Vertical pole without side screen 7-7/8” x 7-7/8” Pole support Floor plate 20x20cm Door pole against the well Ground anchor › Place a drain in post E2 and E3 (poles at the front). Vertical pole with side screen OL-B500-03...
Page 6
› Fix the door profile to the wall with appropriate fixing material . (3) › Fasten the coverplate on the door profile with 2 screws (4.2 x 19) (4) 4.2 x 19 6.3 x 50 M6 x 40 SW10 OL-B500-04...
Page 7
› Fix with self-tapping screws (1) close off the profile with the cover. › Fix the cover with three screws (2). Assembly filler profile on L1 and L2 Assembly filler profile on W1 Self-tapping screw 4.2x13 No hole needs to be drilled L1/L2 OL-B500-05...
Page 8
› Also check the diagonals on the top side. › Further adjust the pole supports a little if necessary. Side view Top view › When everything has been adjusted, firmly tighten all bolts. › Remove any filler pieces used. OL-B500-06...
Page 9
2. Fitting the hinge for the arm profile › Fix the hinge on the coverplate of the vertical pole as shown on the drawing below. 4 x DIN 7982 4.2 x 19 4 x DIN 125 4 x DIN 985 M6 OL-B500-07...
Page 10
(4) › Mark the position of the wall bracket. DIN125 M8 DIN985 M8 DIN125 M8 DIN985 M8 DIN603 M8x25 DIN 7991 M8x90 (DIN7991 M8 x 80 for middle arm) Bolt at the end of the opening OL-B500-08...
Page 11
› Fix the arm on the wall bracket, making sure that the bolt is at the back of the slot. (1) › Place the arms at the front on the hinge piece and tighten the nuts. (2) DIN125 M8 DIN125 M8 DIN985 M8 DIN985 M8 DIN 7991 M8x90 DIN7991 M8x80 DIN125 M8 DIN985 M8 DIN603 M8x25 OL-B500-09...
Page 12
› Check whether the first carriage of each arm is in the same position (measurement A) . › If this is not the case, turn the belt of the arm until they are in the same position. 1. FREE STANDING CONSTRUCTION (ROLLERTUBE IN 1 PART) › Slide the rollertube in the arms. OL-B500-10...
Page 13
› Slide the coupling module from the left-hand and middle part in the right-hand part of the rollertube (5) › Fix th coupling profile to the three parts of the rollertube with 4 bolts (DIN931 M8 x 75) Coupling profile Coupling profile Left-hand part of the rollertube OL-B500-11...
Page 14
› Also fit a motor plate on the bearing side. This stops the rollertube from wandering. Do not fit a nut on the bolt nearest to the arm profile. DIN125 M6 DIN985 M6 DIN125 M6 DIN933 M6x25 No nut on this bolt Bearing side Moto rside No nut on this bolt OL-B500-12...
Page 15
› Fix with a DIN985 M6 nut approximately 10 mm from the end of the arm profile. (2) › Clip locking clips on each hook.(3) (Centre the end of the clips perfectly between the legs of the carriage). DIN 985 M6 OL-B500-13...
Page 16
› Insert a screw DIN916 M5x16 in the end piece to fix the raingutter. DIN 7504 Ø4,2x13 DIN916 M5x16 9. SCREENS 9.a ROLLERTUBES › If 3 screens are provided, always start with the one furthest from the electrical connection. (number 1 in the figure below) Connection 220V Folding fabric motor OL-B500-14...
Page 17
› Bring the screen in accoring to the drawing below (2) and block it on both sides (M4x20) (3). › With poles E1 and E4 (door posts on the wall), fix the rollertube support with bolts (2 x M6x25). Fit ring only if no rollertube support is mounted OL-B500-15...
Page 18
› For this, drill a hole in the aluminium plate on the pole and seal with silicone. (2) › The connection is explained later. WITHOUT SIDESCREEN WITH SIDESCREEN Cable screen motor (no. 2 in fugure 9a) Cable screen motor (no. 1 in fugure 9a) Cable screen motor (no. 3 in fugure 9a) OL-B500-16...
Page 19
› Take care when opening the guide. › Start opening the guide with the upper clips and work clip by clip downwards. › Always pull on the cover profile as near as possible to the clips or the cover profile may distort. OL-B500-17...
Page 20
› Set the folding fabric so the first flowprofile passes over the gutter on the W1 side(1) › Sliding the last flowprofile backwards will put more tension on the fabric. (2) › Sliding the last fabric profile forwards allow the leadrail to pass further over the gutter.(2) OL-B500-18...
Page 21
13.b COVER POLES › Provide each pole with a cover and tighten the remaining screws in the coverplate. › The covers can be mounted in two ways. SINGLE DOOR PROFILE 1x DIN7982 4.2x19 2x DIN7982 4.2x19 Don't screw here OL-B500-19...
Page 22
› Postition the fabric fixation profile on the wall and mark where you are going to fix it. › Screw the fabric fixation profile tigh to the wall every one and a half metres. › Push the rubber seal in the fabric fixation profile to cover the screws. Rubber seal OL-B500-20...
Page 23
› Slide the fabric in the slot on the outside of the arm and pull it up against the wall. 5/8” › Pull the screen cord approximately 15cm back to be able to pull the fabric to the wall. OL-B500-21...
Page 24
› Fasten the side plate on the already assembled cover plate on the bottom of the arm. In the case of side fabric, the side fabric must be punctured in this place. 2 x DIN965 M4 x 10 DIN965 M4 x 10 OL-B500-22...
Page 25
› Position the fixation roof cover 3 mm under the top of the arm profile and fix with self-tapping screws DIN7504 Ø4.2 x 16. (3) 1/8” 2x DIN7504 Ø4,2x16 › Position the roof cover front over the fixation roof cover and drill the holes (1). › Fix with screws DIN7991 M6x20 and nuts. (2) 2x DIN125 Ø6 2x DIN7991 M6x20 2x DIN985 M6 OL-B500-23...
Page 26
› For a fully watertight seal between the wall and the outdoor living area, the installer must apply lead or EPDM in the wall and over the roof cover. Roof Cover Back Silicone DIN7504 Ø4,2x13 Roof Cover 3/8” Silicone OL-B500-24...
Need help?
Do you have a question about the B500 and is the answer not in the manual?
Questions and answers