F016 L70 897.book Seite 3 Mittwoch, 25. Juli 2012 10:32 10

For Your Safety

Warning! Switch off, remove plug from mains
before adjusting, cleaning or if cable is cut,
damaged or entangled.
Electrical Safety
Your machine is double insulated for safety and re-
quires no earth connection. The operating voltage is
230 V AC, 50 Hz (for non-EU countries 220 V, 240 V
as applicable). Only use approved extension cables.
Contact your Bosch Service Centre for details.
If you want to use an extension cable when operat-
ing your high pressure washer, only the following ca-
ble dimensions should be used:
2
1.5 mm
– max length 20 m
2
2.5 mm
– max length 50 m
Note: If an extension cable is used it must be
earthed and connected through the plug to the earth
cable of your supply network in accordance with pre-
scribed safety regulations.
If in doubt contact a qualified electrician or the near-
est Bosch Service Centre.
WARNING! Inadequate extension cables can be
dangerous. Extension cable,
must be of watertight construction and intended
for outdoor use.
Cable connections should be kept dry and off
ground.
It is recommended for increased electrical safety to
use a Residual Current Device (RCD) with a tripping
current of not more than 30 mA. Always check your
RCD every time you use it.
For products not sold in GB
safety, it is essential that the mains plug attached to
the product is fitted to the power supply cable. The
couplings of connection leads must be protected
against splashes and the coupling sockets on the
leads must be made of rubber or coated with rubber.
Fixing means for the connection leads must be
used.
If the supply cord is damaged, it must be replaced by
a Bosch Service Centre.
Products sold in GB only: Your product is fitted with
an approved 13 A (BS 1363/A) electric plug and is
protected by a 13
A fuse (ASTA Approved to
BS 1362).
If the fitted plug is not suitable for your socket out-
lets, it should be cut off and an appropriate plug fit-
ted in its place.
The severed plug must be disposed of to avoid a
possible shock hazard and should never be inserted
into a 13 A socket elsewhere.
15 • F 016 L70 897 • 12.07
Assembly
Water supply
Use a separator as per EN 12729 Type BA.
Water connection
Screw inlet connector 8 onto machine water inlet
A
connection 12.
/
A
B
the mains water supply and machine.
Connecting high pressure water
supply hose/nozzle
Securely screw high pressure hose 5 onto ma-
C
chine at connection 13.
Inserting the vario-jet/fan power lance 4 into the
D
power gun 3. Depress and turn the vario-jet
power lance 90° clockwise to lock in place.
Adjustments and using
plug and socket
different nozzles
Vario-jet-fan power lance (red colour coded)
Twist the front ring to adjust from a pencil to a fan
E
jet and vice versa.
Roto power lance (red colour coded)
Turn the vario-jet /fan power lance 4 90 ° anti-
I
clockwise. Extract the vario-jet/fan power lance.
Insert the
: WARNING: For
J
gun 3. Depress and turn the roto-power lance 90 °
clockwise to lock in place.
Detergent nozzle and bottle
AQUATAK 110
Turn the power lance 90° anti-clockwise. Extract
I
the power lance.
Insert the detergent-nozzle
F
gun 3. Depress and turn the detergent-nozzle 90 °
clockwise to lock in place.
AQUATAK 110 PLUS/115 PLUS
To apply the detergent twist the rear ring as
G
shown from high pressure mode to low pressure
mode.
To adjust the spray pattern twist the front ring.
English - 3
According to the applicable regulations,
the appliance must never be used on the
drinking water network without a system
separator.
Attach water supply hose (not supplied) to
roto-power lance 7 into the power
6 into the power
/fan