5. POINTS TO NOTE
WHEN SETTING UP THE
COMPRESSOR
Examine the machine for signs of transit damage. If there
are any signs of damage, please contact the After Sales
Support on 1300 922 271
The compressor should be set up near the working
consumer.
Avoid long air lines and long supply lines (extensions).
Make sure the intake air is dry and dust-free.
Do not set up the compressor in damp or wet rooms.
The compressor may only be used in suitable rooms
(with good ventilation and an ambient temperature from
+5°C to +40°C). There must be no dust, acids, vapors,
explosive gases or inflammable gases in the room.
The compressor is designed to be used in dry rooms. It is
prohibited to use the compressor in areas where work is
conducted with sprayed water.
The oil level in the compressor pump has to be checked
before putting the equipment into operation.

6. ASSEMBLY AND STARTING

Important!
You must fully assemble the appliance before using it for
the first time.
6.1 Fitting the wheels (3)
Fit the supplied wheels as shown in Fig. 6.
6.2 Fitting the supporting feet (4)
Fit the supplied supporting feet (4) as shown in Fig. 7.
6.3 Replacing the oil sealing plug (14)
Remove the transportation cover from the oil filler opening
with a screwdriver and insert the supplied oil sealing plug
(14) into the oil filler opening (Fig. 8-9).
6.4 Assembly of the air filter
Remove the transportation stop with a screwdriver or similar
and screw the air filter (1) securely to the equipment. (Fig. 10)
6.5. Power supply
The motor is fitted with an overload switch (Fig. 3/Item
16). If the compressor overloads, the overload switch
switches off the equipment automatically to protect the
compressor from overheating. If the overload switch
triggers, switch off the compressor using the ON/OFF
switch (8) and wait until the compressor cools down.
Then press the overload switch (16) and restart the
compressor.
Long supply cables, extensions, cable reels etc. cause a
drop in voltage and can impede motor start-up.
AFTER SALES SUPPORT
1300 922 271
service.australia@einhell.com
In the case of low temperatures below +5°C, motor start-
up is jeopardized as a result of stiffness.
6.6 On/Off switch (8)
To switch on the compressor, pull out the knob (8).
To switch off the compressor, press the knob (8) in again.
(Fig. 2)
6.7 Adjusting the pressure: (Fig. 1)
You can adjust the pressure on the pressure gauge (6)
using the pressure regulator (7).
The set pressure can be taken from the quicklock
coupling (5).
6.8 Setting the pressure switch
The pressure switch is set at the factory.
Switch-on pressure 6 bar
Switch-off pressure 8 bar
7. CLEANING AND
MAINTENANCE
Important!
Pull the power plug before doing any cleaning and
maintenance work on the appliance.
Important!
Wait until the compressor has completely cooled down.
Risk of burns!
Important!
Always depressurise the tank before carrying out any
cleaning and maintenance work.
7.1 Cleaning
Keep the safety devices free of dirt and dust as far as
possible. Wipe the equipment with a clean cloth or blow
it with compressed air at low pressure.
We recommend that you clean the appliance
immediately after you use it.
Clean the appliance regularly with a damp cloth and
some soft soap. Do not use cleaning agents or solvents;
these may be aggressive to the plastic parts in the
appliance. Ensure that no water can get into the interior
of the appliance.
You must disconnect the hose and any spraying tools
from the compressor before cleaning. Do not clean the
compressor with water, solvents or the like.
7.2 Condensation water (Fig. 3)
The condensation water must be drained off after use by
opening the drain valve (11) (on the floor of the pressure
vessel).
9