9. TROUBLESHOOTING

Problem
The compressor does not start
The compressor starts but there is
no pressure
The compressor starts, pressure is
shown on the pressure gauge, but
the tools do not start.
AFTER SALES SUPPORT
1300 922 271
1. No supply voltage
2. Insufficient supply voltage
3. Outside temperature is too low
4. Motor is overheated
1. Leak in the non-return valve
2. The seals are damaged.
3. The drainage valve for
condensation water (11) leaks.
1. Loose hose connections
2. Leak in a quick-lock coupling
3. Insufficient pressure set on the
pressure regulator.
service.australia@einhell.com
Cause
1. Check the supply voltage, the power
plug and the socket-outlet.
2. Make sure that the extension cable is
not too long. Use an extension cable with
wires that are large enough to support
the required voltage.
3. Never operate with an outside
temperature of below +5°C.
4. Allow the motor to cool down. If
necessary, remedy the cause of the
overheating.
1. Replace the non-return valve
2. Check the seals and have any damaged
seals replaced by a service center
3. Tighten the screw by hand. Check
the seal on the screw and replace if
necessary.
1. Check the compressed air hose and
tools and replace if necessary.
2. Check the quick-lock coupling and
replace if necessary.
3. Open the pressure regulator further.
11
MODEL NUMBER: BT-AC 400/50 ,
Solution
09/12