8.2 Condensed water (Fig. 1)
Important! To ensure a long service life of the
pressure vessel (2), drain off the condensed wa-
ter by opening the drain plug (11) each time after
using.
Check the pressure vessel for signs of rust and
damage each time before using. Do not use the
compressor with a damaged or rusty pressure
vessel. If you discover any damage, please con-
tact the customer service workshop.
8.3 Safety valve (10)
The safety valve has been set for the highest per-
mitted pressure of the pressure vessel. It is prohi-
bited to adjust the safety valve or remove its seal.
Actuate the safety valve from time to time to en-
sure that it works when required. Pull the ring with
suffi cient force until you can hear the compressed
air being released. Then release the ring again.
8.4 Cleaning the intake fi lter (1)
The intake fi lter prevents dust and dirt being
drawn in. It is essential to clean this fi lter after at
least every 300 hours in operation. A clogged
intake fi lter will decrease the compressor's per-
formance dramatically. Open the halves of the air
fi lter housing. Use compressed air at low pressure
(approx. 3 bar) to blow out all the parts of the fi lter
and then assemble the fi lter in reverse order.
When cleaning, take adequate precautions
against dust (e.g. use a suitable face mask).
8.5 Storage
Warning!
Pull the mains plug out of the socket and ventilate
the appliance and all connected pneumatic tools.
Switch off the compressor and make sure that it is
secured in such a way that it cannot be started up
again by any unauthorized person.
Warning!
Store the compressor only in a dry location
which is not accessible to unauthorized per-
sons. Always store upright, never tilted!
8.6 Transport
Transport the equipment only by carrying it by
the transport handle.
Protect the equipment against unexpected
knocks and vibrations.
Anl_TE_AC_24_Silent_SPK9.indb 19
Anl_TE_AC_24_Silent_SPK9.indb 19
GB
8.7 Ordering replacement parts:
Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info

9. Disposal and recycling

The equipment is supplied in packaging to pre-
vent it from being damaged in transit. The raw
materials in this packaging can be reused or
recycled. The equipment and its accessories are
made of various types of material, such as metal
and plastic. Never place defective equipment in
your household refuse. The equipment should
be taken to a suitable collection center for proper
disposal. If you do not know the whereabouts of
such a collection point, you should ask in your
local council offi ces.