Disposal And Recycling - EINHELL TC-AC 190/50/8 Original Operating Instructions

Hide thumbs Also See for TC-AC 190/50/8:
Table of Contents

Advertisement

8.3 Safety valve (10)
The safety valve has been set for the highest per-
mitted pressure of the pressure vessel. It is prohi-
bited to adjust the safety valve or remove its seal.
Actuate the safety valve from time to time to en-
sure that it works when required. To do so, open
the screw cap of the valve while the tank is under
pressure. Once the screw cap has been fully ope-
ned you must pull it to let air escape through the
valve. Then screw the cap fully back in place.
8.4 Check the oil level at regular intervals
Place the compressor on a level and straight
surface. The oil level must be between the two
marks MAX and MIN on the oil oil level window
(Fig. 10,11).
Changing the oil: Recommended hydraulic oil:
SAE 5W/40 or an alternative of the same quality.
It should be re lled for the  rst time after 10 hours
of operation. Thereafter the oil should be drained
and re lled after every 100 hours in service.
8.5 Changing the oil
Switch off the engine and pull the mains plug out
of the socket. After releasing any air pressure you
can unscrew the oil drainage screw (15) from the
compressor pump. To prevent the oil from running
out in an uncontrolled manner, hold a small metal
chute under the opening and collect the oil in a
vessel. If the oil does not drain out completely, we
recommend tilting the compressor slightly.
Dispose of the old oil at a drop-off point for
old oil.
When the oil has drained out, re- t the oil draina-
ge screw (15). Fill new oil through the oil  ller ope-
ning (13) until it comes up to the required level.
Then replace the oil sealing plug (14).
8.6 Cleaning the intake  lter (1)
The intake  lter prevents dust and dirt being
drawn in. It is essential to clean this  lter after at
least every 100 hours in operation. A clogged
intake  lter will decrease the compressor's per-
formance dramatically. Undo the screw on the
air  lter so that the halves of the air  lter housing
can be opened. Use compressed air at low pres-
sure (approx. 3 bar) to blow out all the parts of
the  lter and then assemble the  lter in reverse
order. When cleaning, take adequate precautions
against dust (e.g. use a suitable face mask).
GB
8.7 Storage
Warning!
Pull the mains plug out of the socket and ventilate
the appliance and all connected pneumatic tools.
Switch off the compressor and make sure that it is
secured in such a way that it cannot be started up
again by any unauthorized person.
Important!
Store the compressor only in a dry location.
Always store upright, never tilted!
8.8 Ordering replacement parts:
Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.Einhell-Service.com

9. Disposal and recycling

The equipment is supplied in packaging to pre-
vent it from being damaged in transit. The raw
materials in this packaging can be reused or
recycled. The equipment and its accessories are
made of various types of material, such as metal
and plastic. Never place defective equipment in
your household refuse. The equipment should
be taken to a suitable collection center for proper
disposal. If you do not know the whereabouts of
such a collection point, you should ask in your
local council offi ces.
- 17 -

Advertisement

Table of Contents
loading

This manual is also suitable for:

40.073.32

Table of Contents