Calibrating tool

Advertisement

Step 5: Select the corresponding G-number, and then double click to
read the data
Step 6: The software will read the close angle and open angle of the
actuator automatically. The current open and close angles will be
shown on the PC in percentage
Step 7:You can check the if it is the maximum and minimum flow by
changing the slider in the "Move Actuator" box
If yes, you do not need to change any parameter, because it is the best
one already.
If no, you need to adjust the value. See step 8. Adjustment of Angle
Value.
Step 8: Adjustment of Angle Value
1) If move the progress bar to the far right of the "Close angle", the
flow of the turbo assembly is bigger than expect, then need to
decrease its value. The specified value should be determined by
10