SACER E-ACTUATOR SA1478 Manual

Calibrating tool

Advertisement

Quick Links

E-ACTUATOR CALIBRATING TOOL
Manual
Version 2.0

Advertisement

loading

Summary of Contents for SACER E-ACTUATOR SA1478

  • Page 1 E-ACTUATOR CALIBRATING TOOL Manual Version 2.0...
  • Page 2: Table Of Contents

    Content ..3 Application of E-ACTUATOR CALIBRATING TOOL BOM List .............. Software Installation Instruction ........E-ACTUATOR CALIBRATING TOOL Connection ..Functions of E-ACTUATOR CALIBRATING TOOL Software Optional Interface ........Operational Instruction of the Software ....Common Troubleshooting ........
  • Page 3: Application Of E-Actuator Calibrating Tool

    Real-time simulation test Notice:  A. The SA1478 calibrating tool is applied to Sacer SA1140-S E-Actuator only; it may not available for other brands’ actuators. B. The software will be continuously update and will be compatible for more Sacer E-Actuators in the future.
  • Page 4: Bom List

    BOM List Name Quantity Photo E-ACTUATOR CALIBRATING TOOL 12V Power Adapter Huntkey HKA04812040-7D 12V Power Cable (Selections: EU/US/UK) Turbo Actuator Connecting Cable USB Cable E-ACTUATOR CALIBRATING TOOL Manual...
  • Page 5: Software Installation Instruction

    Software Installation Instructions Note: This software is applicable to Windows system 7/8/10 1) TACsetup.exe Double click on the installation file called TACsetup.exe 2) C:\Program Files\TACalibrator Select the installation address, default address: C:\Program Files\TACalibrator 3) Complete the installation (When the installation finished, TAC will be shown on the desk)
  • Page 6: E-Actuator Calibrating Tool Connection

    E-ACTUATOR CALIBRATING TOOL Connection Correct device setup is shown in Figure. Connect the device to DC power supply S by using power cable Turbo actuators are connected with the TC cable.
  • Page 7: Functions Of E-Actuator Calibrating Tool

    Functions of E-ACTUATOR CALIBRATING TOOL 5.1 Reading actuator After successful reading of the parameters the following options are available: 5.2 Parameters This will display actuator parameters on PC: Figure above explains operating range of geometry lever. Maximum angle that can be achieved by moving lever is 120° . Actual operating range for specific actuator can be different.
  • Page 8: Software Optional Interface

    Software Optional Interface 1. On/Off button: Click “On” button, the green light will be on, which indicates the E-ACTUATOR CALIBRATING TOOL works normally 2. Color green shows the normal status of PWM signal 3. Double click the pattern which has been set 4.
  • Page 9: Operational Instruction Of The Software

    Operating Instruction of the Software Step1: Please confirm if the hardware has been connected and powered on successfully, and then assemble the actuator to the turbo assembly, so that you can debug your actuator through the software Step 2: When all connections are ready, open the software. Step 3: Open or close the device by click on the On/Off bottom Step 4:...
  • Page 10 Step 5: Select the corresponding G-number, and then double click to read the data Step 6: The software will read the close angle and open angle of the actuator automatically. The current open and close angles will be shown on the PC in percentage Step 7:You can check the if it is the maximum and minimum flow by changing the slider in the “Move Actuator”...
  • Page 11 the actual working conditions; on opposing situation, the value should be increased. 2) If move the progress bar to the far left of the “Open angle”, the flow of the turbo assembly is smaller than expect, then the value needs to be increased .The specified value should be determined by the actual working conditions;...
  • Page 12: Common Troubleshooting

    Common Troubleshooting Frequently Asked Solution Question 1) Check if the USB cable is loose and causes bad Device not found! connection 2)Check if the PC has read the device’s information successfully 3)Check if the power cable is loose and causes bad connection Connection Started!...