Switch
DescripDon
posiDon
AC voltage measurement. Press SELECT key to switch between frequency/ duty cycle
measurements.
DC voltage measurement.
Resistance measurement.
Ω
Diode/conDnuity measurement. Press SELECT key to choose diode or conDnuity range.
Capacitance measurement.
Frequency measurement, Press SELECT key to switch between frequency/ duty cycle
Hz
measurements.
Temperature measurement, press SELECT key to choose ℃ or ℉.
℃/℉
Non-contact voltage detector.
NCV
DC current measurement (from 0uA to 6000uA). Press SELECT key to switch to AC
current measurement (from 0uA to 6000uA).
DC current measurement (from 0mA to 600mA). Press SELECT key to switch to AC
current measurement (from 0mA to 600mA).
DC current measurement (from 0A to 10A). Press SELECT key to switch to AC current
measurement (from 0A to 10A).
③Input Terminal
Terminal
A
Input terminal for AC and DC current from 0 to 10.00A (
Input terminal for voltage, resistance, diode, and conDnuity, and temperature posiDve
VΩmA
(+) terminal. AC and DC current from 0uA to 600mA (
600mA).
COM
Common terminal for all measurements, and temperature negaDve (-) terminal.
④ FuncDon Key
SELECT/
Key:
1) Select funcDon: Press SELECT key to choose DC or AC measurement under
DescripDon
10 seconds).
Overload for max
less than
Max 18 hours for
Under
(Diode/ConDnuity) range, press SELECT key can choose
(conDnuity test). Under temperature ranges, press SELECT key to choose Degrees
Celsius or Degrees Fahrenheit. Under ACV ranges, press SELECT key to switch
between Frequency or Duty Cycle measurement.
2) When there is no measurement in 15 minutes, the meter will automaDcally power
off and enter sleep mode. One minute before sleep mode, the buzzer will beep for 5
Dmes to remind user. Press any bu]on or turn the rotary switch will exit the sleep
mode.
3) Press SELECT key to acDve the meter from the sleep mode or hold the SELECT key
down when turn on the meter to cancel auto power off funcDon.
4) TORCH FUNCTION Key: Press TORCH FUNCTION key for more than 2 seconds to turn
on the torch. Press it for more than 2 seconds once again to turn off the torch.
RANGE/REL Key
1) Auto range is the default when you turn on the meter, and the meter displays
"AUTO" symbol. Press RANGE to enter manual range mode. Press RANGE to switch
between the ranges available for the selected funcDon. Hold the RANGE bu]on
down for more than 2 seconds to return to auto ranging,
2) Under capacitance measurement, press REL key to enter relaDve value test mode.
The display is zeroed, and △ symbol appears. Press REL key again to exit relaDve
value test mode.
HOLD/ Light Key
1) HOLD Key : Press HOLD key to enter HOLD mode. The current value will be hold, and
symbol "
" will be displayed. Press HOLD again to exit the HOLD mode.
2)
Light Key: Press HOLD key for more than 2 seconds to turn on the backlight. The
backlight can last for 15 seconds. During 15 seconds, press " " light key for 2
seconds again to turn off the backlight.
⑤ Non-contact voltage detector area.
⑥ Holster, Ba]ery door.
See picture.
4.2 DCV measurement
4.2.1 Insert the black test lead into "COM" terminal, and the red one into "VΩmA"
terminal.
4.2.2 Turn the rotary to switch to " " ranges. Under Auto Range status, it will display
"AUTO" symbol. Press "RANGE/REL" key can change to Manual range, the available
ranges.