Download Print this page

TECPEL DMM-8007A Operation Manual

Advertisement

Quick Links

DIGITAL MULTIMETER
OPERATION MANUAL
1. GENERAL
The instrument is a stable and good performance digital multimeter driven by battery.
It uses the LCD with 42mm-high figure to make the reading clear. Unit symbol
displaying, backlight and the function of overload protection make operation is
convenient.
The instrument has the function of measuring DCV, ACV, DCA, ACA, resistance,
capacitance, inductance, temperature and frequency, and diode, triode and
continuity test. The instrument takes dual-integral A/D converter as key point, is an
excellent tool.
2. SAFETY NOTES
This series meter meets the standard of IEC1010. Please read below notes
carefully before operation.
1.Do not input a limited voltage which RMS is over DC 1000V or AC 700V when
measuring voltage.
2.Voltage less than 36V is a safety voltage. When measuring voltage higher than
DC 36V, AC 25V, check the connection and insulation of test leads to avoid electric
shock.
3.Be sure to keep the test leads off the testing point when converting function and
range.
4.Select correct function and range to avoid fault operation.
5.When measuring current, do not input current over 20A.
6.Safety symbols
"
" exists high voltage, "
"GND, "
" dual insulation, "
"
" low battery
3. SPECIFICATION
1) GENERAL
1-1.Displaying : LCD displaying
1-2.Max. indication: 1999(3 1/2), auto polarity indication
1-3.Measuring method: dual slope A/D transfer
1-4.Sampling rate: approx. 3 times/sec
1-5.Over range indication: MSD displays "OL"
1-6.Low battery indication: "
" symbol displays
1-7.Operation: 0~40℃,relative humidity <80%
1-8.Power:one 9V battery (NEDA1604/6F22 or equivalent)
1-9.Size: 190×88.5×27.5 mm
1-10.Weight: approx.422g (including 9V battery)
2) TECHNICAL DATA
2-1. Accuracy: ± (a% × reading + dgts) at (23 ± 5)℃, relative humidity<75%. One
year guarantee since production date.
2-2. Function:
·DCV
·Resistance
Ω
·Diode continuity testing
·ACV
h
·DCA
·Triode
FE
·Capacitance C
·ACA
· Backlight
·True RMS
2-3. TECHNICAL DATA
2-3-1. DC Voltage
Input resistance:All range is 10MΩ
Range
200mV
2V
20V
200V
1000V
Overload protection:Range 200mV: DC 250V or AC peak value
2-3-2. AC Voltage
Range
200mV
2V
20V
200V
750V
Input impedance:All range is 10MΩ;
The frequency response of the standard sine wave and triangular wave is 40Hz
~1kHz.
The frequency response of other waves is 40Hz ~200Hz
2-3-3. DCA
Range
200μA
2mA
20mA
200mA
20A
" must refer to manual,
Max. measuring voltage drop: 200mV;
Max. input current: 20A (within 10 seconds)
Overload protection: 0.2A / 250V fuse ;20A/250V fast-melt fused.
2-3-4. ACA
Range
200μA
2mA
20mA
200mA
20A
Max. measuring voltage drop: 200mV
Max. input current: 20A (within 10 second)
Overload protection:0.2A / 250V fuse ;20A/250V fast-melt fused.
Frequency response:sine and triangular wave: 40Hz~1kHz
Displaying: True RMS
2-3-5. Resistance(Ω)
Range
200Ω
·Temperature ℃
2kΩ
f
·Frequency
20kΩ
L
·Inductance
200kΩ
·Auto power-off
2MΩ
20MΩ
Accuracy
Resolution
0.1mV
0.001V
±(0.5%+3)
0.01V
0.1V
±(0.8%+10)
1V
Other ranges: DC 1000V or AC peak value
Accuracy
Resolution
0.1mV
1mV
±(0.8%+5)
10mV
100mV
±(1.2%+10)
1V
Accuracy
Resolution
0.1μA
0.001mA
±(0.8%+10)
0.01mA
0.1A
±(2.0%+5)
0.01A
Accuracy
Resolution
0.1μA
0.001mA
±(0.8%+10)
0.01mA
0.1A
±(2.0%+5)
0.01A
Other wave: 40Hz~200Hz
Accuracy
Resolution
± (0.8%+5)
0.1Ω
10Ω
± (0.8%+3)
100Ω
1kΩ
± (1.0%+25)
10kΩ
200MΩ
± (5.0% + 30)
Open voltage:less than 3V
Overload protection:DC 250V or AC peak value
NOTE:
A:At range 200 Ω, short-circuit the test leads to measure the wire
resistance, then, subtracts it from the real measurement.
B:The reading be displayed slowly when the measurement is more than 1 MΩ.
Please wait it to be stable.
2-3-6. Capacitance
Range
Accuracy
20nF
200nF
±(3.5%+20)
2uF
20uF
200uF
±(5.0%+10)
2mF
Overload protection:DC 250V or AC peak value
2-3-7. Inductance (L)
Range
Accuracy
2mH
20mH
200mH
±(2.5%+30)
2H
20H
Overload protection:DC 36V
DO NOT INPUT VOLTAGE AT THIS RANGE
2-3-8. Temperature
Range
Accuracy
±(1.0%+5) < 400℃
(-20 ~ 1000)℃
±(1.5%+15) ≥ 400℃
±(0.75%+5) < 750°F
(0~1832)°F
±(1.5%+15) ≥ 750°F
2-3-9. Frequency
Range
Accuracy
10Hz
100Hz
1kHz
±(0.1%+3)
10kHz
100kHz
1MHz/20MHz
Input sensitivity:1V RMS
Overload protection:DC 250V or AC peak value (within 10 seconds)。
2-3-10. Diode and continuity testing
Range
Reading
Forward voltage drop of diode
Buzzer makes a long sound
while resistance is less than
70Ω±20Ω
Overload protection:DC 250V or AC peak value
100kΩ
Resolution
10pF
100pF
1nF
10nF
100nF
1uF
Resolution
1uH
10uH
100uH
1mH
10mH
Resolution
1℃
1°F
Resolution
0.01Hz
0.1Hz
1Hz
10Hz
100Hz
1kHz/10kHz
Condition
Forward DCA is approx.
1mA, the backward
voltage is approx 3V
Open voltage is approx.
3V

Advertisement

loading

Summary of Contents for TECPEL DMM-8007A

  • Page 1 2-3-1. DC Voltage 200MΩ ± (5.0% + 30) 100kΩ DIGITAL MULTIMETER Input resistance:All range is 10MΩ Open voltage:less than 3V Overload protection:DC 250V or AC peak value Range Accuracy Resolution NOTE: A:At range 200 Ω, short-circuit the test leads to measure the wire OPERATION MANUAL 200mV 0.1mV...
  • Page 2 CAUTION:DO NOT INPUT VOLTAGE AT THIS RANGE! the knob to the higher. 4-9. DIODE AND CONTINUITY TEST 2. Max. input current is 200mA or 20A (subject to where the red test lead apply to) , 2-3-11. Transistor h DATA TEST 1.