  • Page 1 Keysight MXR2RACK Rack Mount Kit for MXR-Series Oscilloscopes Installation Guide...
  • Page 2 Further, to the maximum extent permitted and written consent from Keysight Technolo- by applicable law, Keysight disclaims all gies, Inc. as governed by United States and warranties, either express or implied, with CAUTION international copyright laws.
  • Page 3: In This Guide

    In This Guide This guide contains instructions for installing the Keysight MXR2RACK Rack Mount Kit for MXR-Series Oscilloscopes. The rack mount kit provides a support shelf and hardware for mounting Infiniium MXR-Series oscilloscopes into Electronic Industries Association (EIA) standard 19-inch (487-mm) rack cabinets.
  • Page 4 Top clamp bracket (L) (54925-01213) Top trim plate (54925-24111) BNC connectors (1250-2199) Two side trim plates (54925-24113) Hole plugs (6960-0041) Top clamp bracket (R) (54925-01212) Support tray Bottom trim plate (54925-00411) (54925-24112) Clamp brackets (54925-01211) Track rails (54925-03711) Rack Mount Kit for MXR-Series Oscilloscopes Installation Guide...
  • Page 5: Installation

    Installation The following tools are required for installing the rackmount kit: • T20 Torx driver • #2 Phillips screwdriver Preparing the Rack 1 To prepare the rack for sheet metal nut installation, eight rack mount units must be designated for use. The following diagram shows how to determine a rack unit.
  • Page 6 2 Attach 12 nuts, 0590-0804, to test rack as shown in the following figures: Rack Mount Kit for MXR-Series Oscilloscopes Installation Guide...
  • Page 7 Nuts 1 - 8: 8U, Total Rack Mount Kit height Refer to indicator arrows on test rack posts to place nuts. Rack Mount Kit for MXR-Series Oscilloscopes Installation Guide...
  • Page 8 Nut 9: One slot below Nut 3 as below: 12.7mm (1 slot below nut #3) Rack Mount Kit for MXR-Series Oscilloscopes Installation Guide...
  • Page 9 Nut 10: Same height as Nut 9, internal right post. Nut 11: Same position and level as Nut 9 but on left rack post. Nut 12: Same position and level as Nut 10 but on internal left rack post. Rack Mount Kit for MXR-Series Oscilloscopes Installation Guide...
  • Page 10 3 Attach the track rails, 54925-03711, to test rack using screws, 3030-1782. Rack Mount Kit for MXR-Series Oscilloscopes Installation Guide...
  • Page 11 Installing the Oscilloscope into the Rack 1 Facing the back of the oscilloscope, remove screw on top left side: 2 Attach the Top Clamp Bracket (R), 54925-01212 with a 0515-0435 screw. 3 Facing the back of the oscilloscope, remove screw on top right side: Rack Mount Kit for MXR-Series Oscilloscopes Installation Guide...
  • Page 12 4 Attach Top Clamp Bracket (L), 54925-01213 with 0515-0435 screw. 5 Remove the screws above the back feet from both bottom sides of the oscilloscope. Rack Mount Kit for MXR-Series Oscilloscopes Installation Guide...
  • Page 13 6 Place the oscilloscope on top of the support tray, 54925-00411. Make sure the stoppers on the support tray fit into the slots of both bottom rear feet. Rack Mount Kit for MXR-Series Oscilloscopes Installation Guide...
  • Page 14 7 To have front access to the oscilloscope’s rear panel I/Os, route BNC cables underneath the oscilloscope. Also, route the MSO cable underneath the oscilloscope if you need to access to the MSO cables from the front. 8 Attach the clamp brackets, 54925-01211, to the support tray, 54925-00411, using screws 0515-0435 at both sides.
  • Page 15 9 Attach the clamp brackets, 54925-01211 to the oscilloscope using screws, 0515-0436 at both sides. 10 Slide the support tray (with the oscilloscope) into the test rack on the rails. Ensure tabs on the support tray are underneath rails. Rack Mount Kit for MXR-Series Oscilloscopes Installation Guide...
  • Page 16 11 Attach BNC connectors, 1250-2199, to Bottom Trim Plate, 54925-24112. Cover unused holes with Plug, 6960-0041. 12 Connect BNC cables to connector and route MSO cable through cable slot on bottom trim plate. Rack Mount Kit for MXR-Series Oscilloscopes Installation Guide...
  • Page 17 13 Attach Bottom Trim Plate to test rack using screws, 3030-1768. 14 Attach top trim plate, 54925-24111, to test rack using screws, 3030-1768. Rack Mount Kit for MXR-Series Oscilloscopes Installation Guide...
  • Page 18 15 Attach side trim plates, 54925-24113, to test rack using Screws, 3030-1768 on left and right side. Rack Mount Kit for MXR-Series Oscilloscopes Installation Guide...
  • Page 19 The oscilloscope is now fully installed in the rack and should look similar to the following picture. Rack Mount Kit for MXR-Series Oscilloscopes Installation Guide...
  • Page 20 • Width: 1.9 cm (0.748 in) • Height: 3.34 cm (1.32 in) • Height: 2.07 cm (0.815 in) The following diagrams show the dimensions of an Infiniium MXR-Series oscilloscope in an MXR2RACK rack mount. 44.5 cm 22.4 cm 31.1 cm 32.8 cm...
  • Page 21 Rack Mount Kit for MXR-Series Oscilloscopes Installation Guide...
  • Page 22 Rack Mount Kit for MXR-Series Oscilloscopes Installation Guide...
  • Page 23 Rack Mount Kit for MXR-Series Oscilloscopes Installation Guide...
  • Page 24 This information is subject to change without notice. © Keysight Technologies, Inc. 2020 Printed in Malaysia First edition, April 2020 *54925-97002* 54925-97002 www.keysight.com...