Set U Group (Utilities); Set Wet Activation; Set Units; Set Norm Deep Stop - Sherwood Scuba AMPHOS AIR 2.0 Manual

Table of Contents

Advertisement

SET U GROUP (UTILITIES)

Selections >> Wet Activation > Units > Deep Stop > Safety Stop > Conservative Factor > Backlight Duration > Sampling Rate > TRT 1 > TRT 2.
> A + S (2 sec), while viewing Set A, will access Set U (Fig. 48).
> A (< 2 sec) will then access Set Wet Activation.
SET WET ACTIVATION, information includes (Fig. 49):
> Graphic OFF (or ON) flashing.
> Graphics Activ WET.
• S (< 2 sec) will toggle between ON and OFF.
• A (< 2 sec) will save the setting and access Set Units.
• A + S (2 sec) will save the setting and revert to Set U.
• M (2 sec), or if no button is pressed within 2 minutes, operation will revert to the Surface Main.
SET UNITS, information includes (Fig. 50):
> FT and PSI (or BAR and M) icons flashing.
> Graphics UNIT.
• S (< 2 sec) will toggle between Imperial and Metric.
• A (< 2 sec) will save the setting and access Set Deep Stop.
• A + S (2 sec) will save the setting and revert to Set U.
• M (2 sec), or if no button is pressed within 2 minutes, operation will revert to the Surface Main.
SET NORM DEEP STOP, information includes (Fig. 51):
> Graphic OFF (or ON) flashing.
> Graphics dEEP STOP.
• S (< 2 sec) will toggle between OFF and ON.
• A (< 2 sec) will save the setting and access Set Safety Stop.
• A + S (2 sec) will save the setting and revert to Set U.
• M (2 sec), or if no button is pressed within 2 minutes, operation will revert to the Surface Main.
When the Deep Stop is set On, a Stop scren will appear upon ascent to within 10 FT (3 M) below the calculated Stop Depth which is at 1/2
the Max Depth achieved after being deeper than 80 FT (24 M) for 1 second.
SET NORM SAFETY STOP, information includes (Fig. 52):
> Graphic OFF (or ON) flashing.
> Graphics SAFEtY STOP.
• S (< 2 sec) will toggle between OFF and ON.
• A (< 2 sec) will save the setting and access Set Conservative Factor.
• A + S (2 sec) will save the setting and revert to Set U.
• M (2 sec), or if no button is pressed within 2 minutes, operation will revert to the Surface Main.
When the Safety Stop is set On, a Stop screen will appear upon ascent to 20 FT (6 M) indicating that a Stop is to be taken at 15 FT (5 M)
for 3 minutes after being deeper than 30 FT (9 M) for 1 second.
SET CONSERVATIVE FACTOR (CF), information includes (Fig. 53):
> Graphic OFF (or ON) flashing.
> Graphics CF.
• S (< 2 sec) will toggle between OFF and ON.
• A (< 2 sec) will save the setting and access Set Backlight Duration.
• A and S (simultaneously for 2 sec) will save the setting and revert to SET U.
• M (2 sec), or if no button is pressed within 2 minutes, operation will revert to the Surface Main.
When the CF is set ON, NDLs are reduced to those that would be available at the next higher 3000 foot (915 meter) Altitude.
SET BACKLIGHT DURATION, information includes (Fig. 54):
> Graphic OFF (or ON) flashing.
> Graphics dur GLO.
> Duration time (min) with min icon.
• S ( < 2 sec) will step through the selections OFF, ON, and SEt.
• A (< 2 sec) will save the selection -
>> if ON or OFF is saved, advance to Set Sampling Rate.
>> if SEt is saved, the Time digits flash (SEt goes solid).
• S (< 2 sec) will toggle between 5 and 10 (seconds).
• A (< 2 sec) will save the setting and flash SEt allowing ON or OFF to be selected.
• A + S (2 sec) will save the setting and revert to Set U.
• M (2 sec), or if no button is pressed within 2 minutes, operation will revert to the Surface Main.
When the Backlight Duration is set On, the Backlight will remain On for the time set after the L button is pressed/released.
© Pelagic, 2019
19
AMPHOS AIR 2.0 DC MANUAL
Fig. 48 - SET U GROUP
Fig. 49 - SET WET
ACTIVATION
Fig. 50 - SET UNITS
Fig. 51 - SET DEEP STOP
Fig. 52 - SET SAFETY STOP
Fig. 53 - SET CONSERVA-
TIVE FACTOR
Fig. 54 - SET BACKLIGHT
DURATION
Doc. No. 12-79 3 9 -r01 (11/12/19 )

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents