SET EDT ALARM, information includes (Fig. 43):
> Graphic ON (or OFF), flashing.
> Elapsed Dive Time (hr:min).
> Graphic EDT.
• S ( < 2 sec) will step through the selections OFF, ON, and SEt.
• A (< 2 sec) will save the selection -
>> if ON or OFF is saved, advance to Set NIBG Alarm.
>> if SEt is saved, the Time digits flash (SEt goes solid).
• S (hold) will scroll upward from 0:10 to 3:00 (hr:min) in 0:05 (5 min) increments at 8 per sec.
• S ( < 2 sec) will step up through the Set Points one at a time.
• A (< 2 sec) will save the setting and flash SEt allowing ON or OFF to be selected..
• A + S (2 sec) will save the setting and revert to Set A.
• M (2 sec), or if no button is pressed within 2 minutes, operation will revert to the Surface Main.
SET NIBG ALARM, information includes (Fig. 44):
> Graphic ON (or OFF), flashing.
> Bar graph segments with N2 icon.
> Graphic NIBG.
• S ( < 2 sec) will step through the selections OFF, ON, and SEt.
• A (< 2 sec) will save the selection -
>> if ON or OFF is saved, advance to Set DTR Alarm.
>> if SEt is saved, the bar graph segments flash (SEt goes solid).
• S (< 2 sec) will step up from 1 to 5 segments one segment at a time.
• A (< 2 sec) will save the setting and flash SEt allowing ON or OFF to be selected.
• A + S (2 sec) will save the setting and revert to Set A.
• M (2 sec), or if no button is pressed within 2 minutes, operation will revert to the Surface Main.
SET DTR (DIVE TIME REMAINING or RESERVE TIME) ALARM, information includes (Fig. 45):
> Graphic ON (or OFF), flashing.
> Reserve Time (min) with min icon.
> Graphic DTR.
• S ( < 2 sec) will step through the selections OFF, ON, and SEt.
• A (< 2 sec) will save the selection -
>> if ON or OFF is saved, advance to Set Turn Alarm.
>> if SEt is saved, the Time digits flash (SEt goes solid).
• S (hold) will scroll upward from 5 to 20 (min) in 1 min increments at 4 per sec.
• S ( < 2 sec) will step up through the Set Points one at a time.
• A (< 2 sec) will save the setting and flash SEt allowing ON or OFF to be selected.
• A + S (2 sec) will save the setting and revert to Set A.
• M (2 sec), or if no button is pressed within 2 minutes, operation will revert to the Surface Main.
SET TURN ALARM (TRT 1 only), information includes (Fig. 46):
> Graphic ON (or OFF), flashing.
> Graphic trn with Tank 1 icon.
> Pressure with PSI (or BAR) icon.
• S ( < 2 sec) will step through the selections OFF, ON, and SEt.
• A (< 2 sec) will save the selection -
>> if ON or OFF is saved, advance to Set End Alarm.
>> if SEt is saved, the Pressure digits flash (SEt goes solid).
• S (hold) will scroll upward from 1000 to 3000 PSI (70 to 205 BAR) in 250 PSI (5 BAR) increments at 8 per sec.
• S ( < 2 sec) will step up through the Set Points one at a time.
• A (< 2 sec) will save the setting and flash SEt allowing ON or OFF to be selected..
• A + S (2 sec) will save the setting and revert to Set A.
• M (2 sec), or if no button is pressed within 2 minutes, operation will revert to the Surface Main.
SET END ALARM (TRT in use), information includes (Fig. 47):
> Graphic ON (or OFF), flashing.
> Graphic End with Tank 1 and 2 icons.
> Pressure with PSI (or BAR) icon.
• S ( < 2 sec) will step through the selections OFF, ON, and SEt.
• A (< 2 sec) will save the selection -
>> if ON or OFF is saved, revert to Set A.
>> if SEt is saved, the Pressure digits flash (SEt goes solid).
• S (hold) will scroll upward from 300 to 1500 PSI (20 to 105 BAR) in 100 PSI (5 BAR) increments at 8 per sec.
• S ( < 2 sec) will step up through the Set Points one at a time.
• A (< 2 sec) will save the setting and flash SEt allowing ON or OFF to be selected..
• A + S (2 sec) will save the setting and revert to Set A.
• M (2 sec), or if no button is pressed within 2 minutes, operation will revert to the Surface Main.
© Pelagic, 2019
18
AMPHOS AIR 2.0 DC MANUAL
Fig. 43 - SET EDT ALARM
Fig. 44 - SET NiBG ALARM
Fig. 45 - SET DTR ALARM
Fig. 46 - SET TURN ALARM
Fig. 47 - SET END ALARM
Doc. No. 12-79 3 9 -r01 (11/12/19 )