1.0 SAFETY INFORMATION
The provision of the electrical supply and the connection of the unit to the mains must be
carried out by a qualified electrician.
Isolate from power supply before removing any covers. During installation / maintenance ensure
all covers are fitted before switching on the mains supply.
All-pole disconnection from the mains as shown in the wiring diagram must be incorporated
within the fixed wiring and shall have a minimum contact separation of 3mm in accordance with
latest edition of the wiring regulations.
This unit must be earthed.
Ducting must be securely fixed with screws to the spigot to prevent access to live parts. Duct
runs terminating close to the fan must be adequately protected by suitable guards.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
Precautions must be taken to avoid the back-flow of gases into the room from the open flue of
gas or other fuel-burning appliances.
This appliance should not be used by children or persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge, unless they have been given supervision
or instruction concerning the safe use of the appliance by a person responsible for their safety.
Children shall not play with the appliance. Cleaning and user maintenance shall not be carried
out by children.
1.1 Symbols
GENERAL WARNING
Signifies a general warning regarding hazard specified by supplementary information.
ELECTRIC SHOCK
This unit must be completely electrically isolated before any panels are removed. Check
mains supply and control connections.
ROTATING PARTS
This unit contains fast moving rotational parts which may start automatically. It is the
sole responsibility of the installer to adequately guard these components.
REFER TO INSTRUCTION MANUAL
Read and understand the installation and maintenance manual before installing,
operating or maintaining this product.
Nuaire |
Western Industrial Estate
Ecosmart Classic (E) or No (N) Control
Supply & Extract Ventilation with Heat Recovery
Installation Manual
|
|
| nuaire.co.uk
Caerphilly
CF83 1NA
30. 06. 20. Document Number 671948
EMC Directive
2014/30/EU
LVD Directive
2014/35/EU
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Xboxer XBC+ Ecosmart Classic E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for NuAire Xboxer XBC+ Ecosmart Classic E

  • Page 1 REFER TO INSTRUCTION MANUAL Read and understand the installation and maintenance manual before installing, operating or maintaining this product. Nuaire | | nuaire.co.uk 30. 06. 20. Document Number 671948 Western Industrial Estate...
  • Page 2: Personal Protective Equipment

    •Reusable Half Mask Respirators - when replacing filters which have been in contact with normal room or environmental air. Nuaire would always recommend a site specific risk assessment by a competent person to determine if any additional PPE is required.
  • Page 3: Mechanical Installation

    Bottom access units are highly recommended for this type of application. Contact Nuaire for advice. ** This units coastal finish has been designed to withstand an External C4 Atmospheric Corrosivity Category as per BS EN ISO 12944-2:2017 providing that it is installed and maintained as per the manufacturer’s...
  • Page 4 LPHW or Electric Heater Battery Note: The unit is shipped with four G4 filters in place, two of which are included as spares. For F7 filters contact Nuaire. Note: The unit is shipped with four G4 filters in place, two of which are included as spares. For F7 filters contact Nuaire.
  • Page 5 1796 1000 2 attenuator flange connections are attached to every unit. Add 60mm to dimension 'A' to include both flanges for standard (no roof) † units. Nuaire | | nuaire.co.uk 30. 06. 20. Document Number 671948 Western Industrial Estate Caerphilly...
  • Page 6 3.7 Flange Connector Dimensions (mm) Flange Connector INTAKE / SUPPLY / EXTRACT DISCHARGE Dimensions to Hole Centres (mm) Unit Code XBC10HA-***-*** XBC15HA-***-*** XBC25HA-***-*** XBC45HA-***-*** XBC55HA-***-*** XBC65HA-***-*** Nuaire | | nuaire.co.uk 30. 06. 20. Document Number 671948 Western Industrial Estate Caerphilly CF83 1NA...
  • Page 7: Dimensions (Mm)

    1600 XBC65-HE-MS16* 1600 2 attenuator flange connections are attached to every unit. Add 60mm to dimension 'A' to include both flanges for standard (no roof) units. Nuaire | | nuaire.co.uk 30. 06. 20. Document Number 671948 Western Industrial Estate Caerphilly...
  • Page 8 HS - Denotes the type of silencer required for the supply or discharge. HE - Denotes the type of silencer required for the extract or intake. *Note: XBC15 silencers are also suitable for XBC10 units. Nuaire | | nuaire.co.uk 30. 06. 20. Document Number 671948...
  • Page 9: Unit Installation

    •Fix brackets to drop rods to support attenuators •Use the 2 x Ø5.3mm holes on the attenuator brackets to position attenuator and fix self tapping screws in position. Nuaire | | nuaire.co.uk 30. 06. 20. Document Number 671948 Western Industrial Estate Caerphilly...
  • Page 10 Silencers Belimo SM230A-S drive open/drive close actuator complete with switch. Motorised Damper Nuaire | | nuaire.co.uk 30. 06. 20. Document Number 671948 Western Industrial Estate Caerphilly CF83 1NA...
  • Page 11 Notes: parts. Caution Power supply voltage. Nuaire recommend the pressure switch be set to trigger when the Other actuators can be connected in parallel. filters experience a 125 Pa increase above the clean filter resistance for Please note the the largest commissioned airflow rate.
  • Page 12 Unit operation will otherwise be unaffected. Nuaire | | nuaire.co.uk 30. 06. 20. Document Number 671948...
  • Page 13: Setting To Work

    Isolation - Before commencing work, make sure that the unit, The electrical wiring must be carried out by competent persons, in switched live and Nuaire control are electrically isolated from the accordance with good industry practice and should conform to all mains supply.
  • Page 14: Electrical Information

    1 = selected connected in the system. The voltage tolerance is +/- 125mV and is Trickle Test TEST = Test button measured at the fans terminal. Nuaire | | nuaire.co.uk 30. 06. 20. Document Number 671948 Western Industrial Estate Caerphilly CF83 1NA...
  • Page 15 •Do not wire the power supply to motor via the motor alarm relay as terminals are only closed after the motor is energized. 5.8.1 Unit Sizes 10-15 Wiring - BC Control - XBC10-15 Nuaire | | nuaire.co.uk 30. 06. 20. Document Number 671948 Western Industrial Estate...
  • Page 16 Installation Manual XBC+ with Ecosmart Classic (E) or No (N) Control 5.8.2 Unit Sizes 25-65 Wiring - BC Control - XBC25-65 Nuaire | | nuaire.co.uk 30. 06. 20. Document Number 671948 Western Industrial Estate Caerphilly CF83 1NA...
  • Page 17 XBC+ with Ecosmart Classic (E) or No (N) Control 5.9 Wiring Diagrams for ES Control 5.9.1 Unit Sizes 10-15 with No Heating Wiring - ES Control - XBC10-15 No Heater Nuaire | | nuaire.co.uk 30. 06. 20. Document Number 671948 Western Industrial Estate...
  • Page 18 Installation Manual XBC+ with Ecosmart Classic (E) or No (N) Control 5.9.2 Unit Sizes 10-15 with No Heating Wiring - ES Control - XBC25-65 No Heater Nuaire | | nuaire.co.uk 30. 06. 20. Document Number 671948 Western Industrial Estate Caerphilly...
  • Page 19 Installation Manual XBC+ with Ecosmart Classic (E) or No (N) Control 5.9.3 Unit Sizes 25-65 with LPHW Heating Wiring - ES Control - XBC10-15 LPHW Heater Nuaire | | nuaire.co.uk 30. 06. 20. Document Number 671948 Western Industrial Estate Caerphilly...
  • Page 20 Installation Manual XBC+ with Ecosmart Classic (E) or No (N) Control 5.9.4 Unit Sizes 25-65 with LPHW Heating Wiring - ES Control - XBC25-65 LPHW Heater Nuaire | | nuaire.co.uk 30. 06. 20. Document Number 671948 Western Industrial Estate Caerphilly...
  • Page 21 Installation Manual XBC+ with Ecosmart Classic (E) or No (N) Control 5.9.5 Unit Sizes 10-15 with Electric Heating Wiring - ES Control - XBC10-15 Electric Heater Nuaire | | nuaire.co.uk 30. 06. 20. Document Number 671948 Western Industrial Estate Caerphilly...
  • Page 22 Installation Manual XBC+ with Ecosmart Classic (E) or No (N) Control 5.9.6 Unit Sizes 25-65 with Electric Heating Wiring - ES Control - XBC25-65 Electric Heater Nuaire | | nuaire.co.uk 30. 06. 20. Document Number 671948 Western Industrial Estate Caerphilly...
  • Page 23: Maintenance

    The product warranty applies to the UK mainland and in accordance with Clause 14 of our Conditions of Sale. Customers purchasing from outside of the UK should contact Nuaire International Sales office for further details. 8.0 END-OF-LIFE AND RECYCLING...
  • Page 24 GENERAL In addition to the particular requirements given for the individual product, the following general requirements The equipment referred to in this Declaration of Incorporation is supplied by Nuaire to be assembled into should be noted. a ventilation system which may or may not include additional components. The entire system must be...

This manual is also suitable for:

Xboxer xbc+ ecosmart classic n

Table of Contents