f) Alternating current (A/AC, clamp measurements)
Range
A
60.00 A
600.0 A
Frequency range 40 – 400 Hz; 600 V overload protection
Specified measuring range: 5 – 100 % of the measuring range
The multimeter may display <2 counts when a measuring input is open
TrueRMS peak (Crest Factor (CF)) ≤3 CF to 600 V
TrueRMS peak for non-sinusoidal signals plus tolerance
CF >1.0 – 2.0
+ 3 %
CF >2.0 – 2.5
+ 5 %
CF >2.5 – 3.0
+ 7 %
g) AC + DC current
Range
60.00 A
600.0 A
600 A overload protection
True RMS applicable for range 5 – 10 %
Frequency range 40 – 400 Hz;
TrueRMS peak (Crest Factor (CF)) ≤3 CF to 600 V
TrueRMS peak for non-sinusoidal signals plus tolerance
CF >1.0 – 2.0
+ 3 %
CF >2.0 – 2.5
+ 5 %
CF >2.5 – 3.0
+ 7 %
70
Resolution
0.01 A
0.1 A
Resolution
0.01 A
0.1 A
Accuracy
40 – 100 Hz
100 – 400 Hz
±(1.8 % + 8)
±(3.5 % + 6)
Accuracy
40 – 100 Hz
100 – 400 Hz
±(3 % + 6)