Check Valve Repair - Graco Mark VII Max Repair Manual

Electric airless sprayers
Hide thumbs Also See for Mark VII Max:
Table of Contents

Advertisement

Check Valve Repair

Check Valve Repair
1. Flush pump. Turn power OFF. Wait 5 minutes for
power to dissipate. Perform Pressure Relief
Procedure, page 9.
2. Separate drain hose from sprayer.
3. Disconnect paint hose from check valve.
4. Remove check valve assembly from pump.
5. Remove check valve outlet fitting.
32
ti18433a
ti18594a
ti18595a
ti18596a
6. Replace o-rings (4), ball housing (2), ceramic ball
(3), and seat (5).
3a
7. Apply pipe sealant to check valve inlet threads.
ti18598a
8. Use 1.5 in. wrench to securely tighten check valve
to pump.
ti18599a
9. Connect paint hose and hand tighten to 70 in-lb
(8 N•m).
1
3b
3c
3d
3c
ti18593a
ti18600a
3A2244A
2