Displacement Pump Replacement

Displacement Pump
Replacement
Removal
1. Flush pump.
2. Stop pump with piston rod in its lowest position.
3. Perform Pressure Relief Procedure, page 9.
4. Separate drain hose from sprayer.
5. Disconnect hose from pump.
NOTE: It is recommended that the check valve be
repaired at the same time as the pump. For check
valve repair, see page 32 (Mark X units only).
6. Raise latch lock. Push latch open.
ti18432a
28
ti18433a
ti18428a
ti18431a
7. Ratchet pump door forward.
8. Twist latch u-bolt out of pump door recess.
9. Place u-bolt on pump door protrusion.
10. Ratchet pump door forward.
11. Open pump door.
12. Pull out pump pin and place in pin holder.
ti6377a
ti18429a
ti18430a